Literature DB >> 7097009

Solid-phase immunoradiometric assay for C-reactive protein using magnetisable cellulose particles.

F C De Beer, M B Pepys.   

Abstract

An immunoradiometric assay (IRMA) for C-reactive protein (CRP) was developed using magnetisable cellulose particles as the solid-phase support for anti-CRP antibodies. 125I-labeled immunopurified anti-CRP antibody was used to quantitate the amount of CRP taken up by the solid phase. Unbound label was easily and rapidly removed by decantation after sedimenting the particles on a magnet. The assay could detect 1 microgram CRP/l and had a range of up to 10 mg/l with the portion of the standard curve between 10 micrograms/l and 2-3 mg/l being linear. Fifty samples per hour could be processed manually from serum to CRP result with an intra-assay CV of 5.2% and an inter-assay CV of 10.0%, based on 5 replicates of 5 samples with CRP levels between 2 mg/l and 180 mg/l run in 5 separate assays. Fifty clinical samples were assayed in parallel with a standard electroimmunoassay and yielded a linear correlation coefficient (r) of 0.975 and a slope of 0.988. With its single, brief incubation step including all reagents and its simple phase separation procedure the present method may be the assay of choice when precise measurement of CRP concentrations is required rapidly.

Entities:  

Mesh:

Substances:

Year:  1982        PMID: 7097009     DOI: 10.1016/0022-1759(82)90168-5

Source DB:  PubMed          Journal:  J Immunol Methods        ISSN: 0022-1759            Impact factor:   2.303


  5 in total

1.  Objective monitoring of disease activity in polyarteritis by measurement of serum C reactive protein concentration.

Authors:  C R Hind; C O Savage; C G Winearls; M B Pepys
Journal:  Br Med J (Clin Res Ed)       Date:  1984-04-07

2.  C reactive protein concentrations during long distance running.

Authors:  A F Strachan; T D Noakes; G Kotzenberg; A E Nel; F C de Beer
Journal:  Br Med J (Clin Res Ed)       Date:  1984-11-10

3.  Value of C reactive protein measurement in tuberculous, bacterial, and viral meningitis.

Authors:  F C de Beer; G F Kirsten; R P Gie; N Beyers; A F Strachan
Journal:  Arch Dis Child       Date:  1984-07       Impact factor: 3.791

4.  Radiometric ligand binding assay for C-reactive protein. Complexed C-reactive protein is not detectable in acute phase serum.

Authors:  F C De Beer; B Shine; M B Pepys
Journal:  Clin Exp Immunol       Date:  1982-10       Impact factor: 4.330

5.  Low density lipoprotein and very low density lipoprotein are selectively bound by aggregated C-reactive protein.

Authors:  F C de Beer; A K Soutar; M L Baltz; I M Trayner; A Feinstein; M B Pepys
Journal:  J Exp Med       Date:  1982-07-01       Impact factor: 14.307