Literature DB >> 7092516

Cementless fixation of polyethylene acetabular component in total hip arthroplasty.

E W Morscher, W Dick, V Kernen.   

Abstract

A new concept of cementless fixation of a polyethylene acetabular component for total hip arthroplasty is presented. The spherical cup is fixed directly to the subchondral bone of the acetabulum by means of two pegs and screws. The polyethylene in direct contact to the bone adjusts to the deformation of the pelvis (Isoelasticity). Bone grows into the indentations of the outer surface of the implant. The elastic cup does not interfere with the physiological stress patterns of the hip joint so that a stable "biomechanical incorporation" of the implant is achieved. A follow-up of the first 250 cementless fixed polyethylene cups with an observation period of six months to four years with an average of 19 months is reported. So far no aseptic loosening of the implant has occurred.

Entities:  

Mesh:

Substances:

Year:  1982        PMID: 7092516     DOI: 10.1007/BF00381397

Source DB:  PubMed          Journal:  Arch Orthop Trauma Surg        ISSN: 0344-8444


  8 in total

1.  [First experiences with a cementlen isoelastic total hip prosthesis].

Authors:  E Morscher; R Mathys
Journal:  Z Orthop Ihre Grenzgeb       Date:  1975-08

2.  [Total isoelastic hip prosthesis implanted without cement. Initial results].

Authors:  E Morscher; R Mathys
Journal:  Acta Orthop Belg       Date:  1974       Impact factor: 0.500

3.  Periacetabular pressure recording, using a hip simulator.

Authors:  P Christel; P Derethe; L Sedel
Journal:  Acta Orthop Belg       Date:  1980       Impact factor: 0.500

4.  Osteogenic phenomena across endosteal bone-implant spaces with porous surfaced intramedullary implants.

Authors:  J D Bobyn; R M Pilliar; H U Cameron; G C Weatherly
Journal:  Acta Orthop Scand       Date:  1981

5.  The development of a two-dimensional stress-optical model of the os coxae.

Authors:  N J Holm
Journal:  Acta Orthop Scand       Date:  1981

6.  Influence of a functional dynamic loading on bone ingrowth into surface pores of orthopedic implants.

Authors:  P Ducheyne; P De Meester; E Aernoudt
Journal:  J Biomed Mater Res       Date:  1977-11

7.  Osseointegrated titanium implants. Requirements for ensuring a long-lasting, direct bone-to-implant anchorage in man.

Authors:  T Albrektsson; P I Brånemark; H A Hansson; J Lindström
Journal:  Acta Orthop Scand       Date:  1981

8.  The treatment of femoral neck fractures with an isoelastic endoprosthesis implanted without bone cement.

Authors:  E Morscher; R Bombelli; R Schenk; R Mathys
Journal:  Arch Orthop Trauma Surg       Date:  1981
  8 in total
  13 in total

1.  [Experiences with the Spotorno expansion acetabulum].

Authors:  K Tittel; B Hogt
Journal:  Unfallchirurgie       Date:  1991-08

2.  Uncoated polyethylene RM acetabular component versus Müller cemented acetabular component. A 4- to 8-year follow-up study.

Authors:  M Krismer; M Fischer; T Klestil; B Frischhut
Journal:  Arch Orthop Trauma Surg       Date:  1991       Impact factor: 3.067

3.  Comparison between straight- and curved-stem Müller femoral prostheses. 5- to 10-year results of 545 total hip replacements.

Authors:  J Wilson-MacDonald; E Morscher
Journal:  Arch Orthop Trauma Surg       Date:  1990       Impact factor: 3.067

4.  Experiments and clinical application of porous ceramic coating.

Authors:  G S Ling; T Y Wang; S P Li; S Z Sun
Journal:  J Tongji Med Univ       Date:  1987

5.  [Initial experience using the new Weill cementless threaded ring in acetabulum replacement].

Authors:  P Kirschner; W Franz
Journal:  Unfallchirurgie       Date:  1987-02

6.  Cementless acetabular replacement using a pegged polyethylene prosthesis.

Authors:  K C Bertin; M A Freeman; E Morscher; A Oeri; P A Ring
Journal:  Arch Orthop Trauma Surg       Date:  1985

7.  Total hip replacement with solid autologous femoral head graft for hip dysplasia.

Authors:  B Hintermann; E W Morscher
Journal:  Arch Orthop Trauma Surg       Date:  1995       Impact factor: 3.067

8.  Implant materials for hip endoprostheses: old proofs and new trends.

Authors:  M Semlitsch; H G Willert
Journal:  Arch Orthop Trauma Surg       Date:  1995       Impact factor: 3.067

9.  Osseous penetration rate into implants pretreated with bone cement.

Authors:  T Albrektsson
Journal:  Arch Orthop Trauma Surg       Date:  1984

10.  Osteolysis around uncoated polyethylene acetabular cups : A seven- to nine-year follow-up of 79 hips.

Authors:  T J Niinimäki; M M Ruuskanen; P K Jalovaara
Journal:  Eur J Orthop Surg Traumatol       Date:  1995-12
View more