Platelet function during cardiac operation: comparison of membrane and bubble oxygenators.

L H Edmunds, N Ellison, R W Colman, S Niewiarowski, A K Rao, V P Addonizio, L W Stephenson, R N Edie.   

Abstract

The effects of cardiopulmonary bypass with bubble and membrane oxygenator systems on platelet function were studied in 26 patients who had elective coronary arterial bypass grafts. Fourteen patients were perfused with spiral coil membrane oxygenator systems, 12 with bubble oxygenator systems. During and after bypass, platelet counts decreased in both groups; however, when corrected for dilution, platelet counts did not change significantly in patients perfused with membrane oxygenators and increased slightly but significantly in those perfused with membrane oxygenators and increased slightly but significantly in those perfused with bubble oxygenator systems. During and 1 hour after bypass, the concentration of adenosine diphosphate (ADP) required to cause complete aggregation increased in both groups. Plasma low affinity platelet factor 4 (LA-PF4) increased significantly during and after bypass in both groups. However, the concentration of platelet adenine nucleotides and LA-PF4, measured only in patients perfused with membrane oxygenator systems, did not change. Bleeding times increased postoperatively in both groups and 18 hour blood losses were similar. Cardiopulmonary bypass with membrane and bubble oxygenator systems causes qualitatively similar losses in sensitivity to ADP and similar increases in bleeding times. The mechanism by which platelets are altered during cardiopulmonary bypass in obscure but is not due to partial depletion of granule contents in patients perfused with membrane oxygenators.

Entities:  

Mesh:

Substances:

Year:  1982        PMID: 7087507

Source DB:  PubMed          Journal:  J Thorac Cardiovasc Surg        ISSN: 0022-5223            Impact factor:   5.209


  5 in total

1.  A comparison of flat-sheet and hollow-fiber membrane oxygenators: the Shiley M-2000 vs. the Bentley BOS-CM 40.

Authors:  M E Bergdahl; L A Bergdahl
Journal:  Tex Heart Inst J       Date:  1989

2.  [Thrombotic microangiopathy after extracorporeal circulation: important differential diagnosis].

Authors:  T Schmidt; D A Tsakiris; M Grapow; M Siegemund
Journal:  Anaesthesist       Date:  2010-12-25       Impact factor: 1.041

3.  Effects of tranexamic acid and aprotinin, two antifibrinolytic drugs, on PAF-induced plasma extravasation in unanesthetized rats.

Authors:  J G O'Brien; B Battistini; F Zaharia; G E Plante; P Sirois
Journal:  Inflammation       Date:  2000-10       Impact factor: 4.092

4.  Bleeding risk assessment using whole blood impedance aggregometry and rotational thromboelastometry in patients following cardiac surgery.

Authors:  Mate Petricevic; Bojan Biocina; Davor Milicic; Sanja Konosic; Lucija Svetina; Ante Lekić; Boris Zdilar; Ivan Burcar; Milan Milosevic; Rifat Brahimaj; Jure Samardzic; Hrvoje Gasparovic
Journal:  J Thromb Thrombolysis       Date:  2013-11       Impact factor: 2.300

5.  Cardiac bypass surgery with haemorrhagic endocrine sequelae.

Authors:  R Khardori; R C Bussing; G M Burns; N G Soler
Journal:  Postgrad Med J       Date:  1987-06       Impact factor: 2.401