Literature DB >> 7085820

Specimen handling and high-performance liquid chromatographic determination of furosemide.

A L Kerremans, Y Tan, C A Van Ginneken, F W Gribnau.   

Abstract

A simple high-performance liquid chromatographic method to measure furosemide in plasma and urine is described. Furosemide fluoresces best, but is unstable, at acidic pH and is subject to photochemical degradation. These factors were analysed and the results prompted changes in previously described methods. All specimens were very carefully protected from light; extraction and acidification were done with acetic acid instead of hydrochloric acid. With these precautions no 4-chloro-5-sulphamoylanthranilic acid was found in biological specimens. The main metabolite was furosemide glucuronide (20% of furosemide excretion). Sensitivity was 0.1 and 0.5 microgram/ml for plasma and urine, respectively. The applicability of our method for furosemide studies is demonstrated.

Entities:  

Mesh:

Substances:

Year:  1982        PMID: 7085820     DOI: 10.1016/s0378-4347(00)86044-2

Source DB:  PubMed          Journal:  J Chromatogr


  2 in total

Review 1.  Furosemide (frusemide). A pharmacokinetic/pharmacodynamic review (Part II).

Authors:  L L Ponto; R D Schoenwald
Journal:  Clin Pharmacokinet       Date:  1990-06       Impact factor: 6.447

2.  Sensitivity of residual nephrons to high dose furosemide described by diuretic efficiency.

Authors:  R W van Olden; J J van Meyel; P G Gerlag
Journal:  Eur J Clin Pharmacol       Date:  1995       Impact factor: 2.953