Literature DB >> 7085717

Energy costs of walking in lower-extremity plaster casts.

R L Waters, J Campbell, L Thomas, L Hugos, P Davis.   

Abstract

The energy cost of walking with axillary crutches and each of three types of plaster casts (long, short, and cylinder) on the lower extremity was measured in twenty normal adult men. The knee and ankle joints were immobilized unilaterally in the neutral positions. Oxygen uptake was measured using a modified Douglas-bag technique. Heart rate, respiratory rate, and step frequency were telemetered from transducers that were attached to the subjects. When walking and bearing full weight on a cast without the use of crutches, the average rates of energy expenditure for subjects wearing the three varieties of casts did not significantly differ from the value for normal walking. Velocity, however, was reduced depending on the extent of immobilization. The average velocity of the subjects was fifty-six meters per minute in a long cast, sixty-four meters per minute in in a cylinder cast, and seventy meters per minute in a short cast, compared with seventy-eight meters per minute without immobilization of the limb. The subjects' average oxygen cost per meter was 0.24 milliliter per kilogram in a long cast, 0.20 milliliter per kilogram in a cylinder cast, and 0.19 milliliter per kilogram in a short cast, compared with 0.15 milliliter per kilogram for normal walking. Using a unilateral non-weight-bearing swing-through gait, the average rate of oxygen uptake for subjects wearing the three types of casts did not differ from the mean value without a cast (21.2 milliliters per kilogram per minute). All values were at least 60 per cent higher than the average for normal level walking.

Entities:  

Mesh:

Year:  1982        PMID: 7085717

Source DB:  PubMed          Journal:  J Bone Joint Surg Am        ISSN: 0021-9355            Impact factor:   5.284


  10 in total

1.  Crutches.

Authors:  B E Potter; W A Wallace
Journal:  BMJ       Date:  1990-11-03

2.  Ankle fixation need not increase the energetic cost of human walking.

Authors:  Matthew T Vanderpool; Steven H Collins; Arthur D Kuo
Journal:  Gait Posture       Date:  2008-03-24       Impact factor: 2.840

3.  Biomechanical effect of electromechanical knee-ankle-foot-orthosis on knee joint control in patients with poliomyelitis.

Authors:  Sungjae Hwang; Sungjae Kang; Kanghee Cho; Youngho Kim
Journal:  Med Biol Eng Comput       Date:  2008-02-08       Impact factor: 2.602

4.  Rehabilitation of the anterior cruciate ligament in the athlete.

Authors:  J P Silfverskiold; J R Steadman; R W Higgins; T Hagerman; J A Atkins
Journal:  Sports Med       Date:  1988-11       Impact factor: 11.136

5.  Gait in thoracolumbar/lumbar adolescent idiopathic scoliosis: effect of surgery on gait mechanisms.

Authors:  Philippe Mahaudens; C Detrembleur; M Mousny; X Banse
Journal:  Eur Spine J       Date:  2010-02-11       Impact factor: 3.134

6.  Very short-term effect of brace wearing on gait in adolescent idiopathic scoliosis girls.

Authors:  Philippe Mahaudens; Xavier Banse; Maryline Mousny; Maxime Raison; Christine Detrembleur
Journal:  Eur Spine J       Date:  2013-05-24       Impact factor: 3.134

7.  Gait in adolescent idiopathic scoliosis: energy cost analysis.

Authors:  P Mahaudens; C Detrembleur; M Mousny; X Banse
Journal:  Eur Spine J       Date:  2009-04-24       Impact factor: 3.134

8.  Walking, orthoses and physical effort in a Swedish population with arthrogryposis.

Authors:  Marie Eriksson; Li Villard; Asa Bartonek
Journal:  J Child Orthop       Date:  2014-06-08       Impact factor: 1.548

Review 9.  Mechanisms and component design of prosthetic knees: A review from a biomechanical function perspective.

Authors:  Wei Liang; Zhihui Qian; Wei Chen; Hounan Song; Yu Cao; Guowu Wei; Lei Ren; Kunyang Wang; Luquan Ren
Journal:  Front Bioeng Biotechnol       Date:  2022-09-15

10.  Wearable monitoring devices for assistive technology: case studies in post-polio syndrome.

Authors:  Giuseppe Andreoni; Marco Mazzola; Paolo Perego; Carlo Emilio Standoli; Simone Manzoni; Luca Piccini; Franco Molteni
Journal:  Sensors (Basel)       Date:  2014-01-24       Impact factor: 3.576

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.