Literature DB >> 708536

Effect of aortic valvular regurgitation upon the impedance cardiogram.

R M Schieken, M R Patel, H L Falsetti, R W Barnes, R M Lauer.   

Abstract

The first derivative thoracic impedance cardiogram, phonocardiogram, and electrocardiogram were recorded in three groups of 22 subjects each. In Group 1 (control), simultaneous impedance cardiogram, phonocardiogram, and aortic valve echocardiograms showed that the X point of the impedance cardiogram occurred synchronously with the aortic second heart sound and with echocardiographic aortic valve closure. In group 2 (clinical diagnosis of aortic regurgitation) the scalar magnitude of the impedance cardiogram O wave and the ratios of the impedance cardiogram wave form X/dz/dtmax and O/dz/dtmax were different from control. In addition, the early diastolic (X) and systolic portions (S) of the impedance cardiogram wave form of group 3 patients were planimetered and expressed as the ratio X/S, called the impedance cardiographic aortic regurgitant fraction (aortic RFI). The aortic RFI was increased by handgrip, a manoeuvre which acutely increases the magnitude of aortic regurgitation. The difference between Fick cardiac output and left ventricular angiographic output was used to calculate aortic valvular regurgitant fraction, which related closely to the impedance cardiogram. These data suggest that it is useful in the noninvasive assessment of aortic regurgitation.

Entities:  

Mesh:

Year:  1978        PMID: 708536      PMCID: PMC483516          DOI: 10.1136/hrt.40.9.958

Source DB:  PubMed          Journal:  Br Heart J        ISSN: 0007-0769


  12 in total

1.  THE CIRCULATIORY EFFECTS OF SUSTAINED VOLUNTARY MUSCLE CONTRACTION.

Authors:  A R LIND; S H TAYLOR; P W HUMPHREYS; B M KENNELLY; K W DONALD
Journal:  Clin Sci       Date:  1964-10       Impact factor: 6.124

2.  Effects of isometric exercise on cardiac performance. The grip test.

Authors:  C Kivowitz; W W Parmley; R Donoso; H Marcus; W Ganz; H J Swan
Journal:  Circulation       Date:  1971-12       Impact factor: 29.690

3.  The Minnesota impedance cardiograph- theory and applications.

Authors:  W G Kubicek; J Kottke; M U Ramos; R P Patterson; D A Witsoe; J W Labree; W Remole; T E Layman; H Schoening; J T Garamela
Journal:  Biomed Eng       Date:  1974-09

4.  Estimation of left ventricular volume by one-plane cineangiography.

Authors:  D G Greene; R Carlisle; C Grant; I L Bunnell
Journal:  Circulation       Date:  1967-01       Impact factor: 29.690

5.  Evaluation of impedance cardiac output in children.

Authors:  Z Lababidi; D A Ehmke; R E Durnin; P E Leaverton; R M Lauer
Journal:  Pediatrics       Date:  1971-05       Impact factor: 7.124

6.  The first derivative thoracic impedance cardiogram.

Authors:  Z Lababidi; D A Ehmke; R E Durnin; P E Leaverton; R M Lauer
Journal:  Circulation       Date:  1970-04       Impact factor: 29.690

7.  Development and evaluation of an impedance cardiac output system.

Authors:  W G Kubicek; J N Karnegis; R P Patterson; D A Witsoe; R H Mattson
Journal:  Aerosp Med       Date:  1966-12

8.  Echocardiographic assessment of left ventricular function in aortic valve disease.

Authors:  I G McDonald
Journal:  Circulation       Date:  1976-05       Impact factor: 29.690

9.  Echocardiographic demonstration of early mitral valve closure in severe aortic insufficiency. Its clinical implications.

Authors:  E H Botvinick; N B Schiller; R Wickramasekaran; S C Klausner; E Gertz
Journal:  Circulation       Date:  1975-05       Impact factor: 29.690

10.  Assessment of aortic insufficiency by transcutaneous Doppler ultrasound.

Authors:  D R Boughner
Journal:  Circulation       Date:  1975-11       Impact factor: 29.690

View more
  3 in total

1.  Simplified electrode array for impedance cardiography.

Authors:  B C Penney; N A Patwardhan; H B Wheeler
Journal:  Med Biol Eng Comput       Date:  1985-01       Impact factor: 2.602

2.  Effect of mitral valvular regurgitation on transthoracic impedance cardiogram.

Authors:  R M Schieken; M R Patel; H L Falsetti; R M Lauer
Journal:  Br Heart J       Date:  1981-02

3.  Mitral regurgitation and characteristic changes in impedance cardiogram.

Authors:  J N Karnegis; J Heinz; W G Kubicek
Journal:  Br Heart J       Date:  1981-05
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.