Literature DB >> 7078139

Ultrasonic measurement of human fetal blood flow.

S H Eik-Nes, K Marsal, A O Brubakk, K Kristofferson, M Ulstein.   

Abstract

Pulsed Doppler technique was combined with real-time B-mode ultrasonography for non-invasive measurement of human fetal blood flow in utero. The fetal vessel, e.g. aorta or umbilical vein, was identified in the real-time image and the real-time transducer put parallel to the vessel. The 2 MHz pulsed Doppler transducer insonated the vessel at a known angle, as the transducers were firmly attached to each other at an angle of 52 degrees. The Doppler instrument processed the Doppler shift signals and estimated the mean and maximum blood velocity. For calculation of blood flow, fetal vessel diameter must be measured. Three ultrasonic techniques (real-time B-mode, TM-mode, Time-distance recording) were applied for diameter measurements. The accuracy of the real-time B-mode technique was tested in vitro on 8 glass tubes with various diameters; the ultrasonically measured diameter was within +/- 0.4 mm of the diameter measured with vernier calipers. The reproducibility of diameter measurement was tested in vivo; the standard deviation of the difference between measurement was 0.15 mm for the fetal aorta and 0.20 mm for the umbilical vein. Fetal blood flow was measured in 38 normal late pregnancies. Blood flow in the thoracic part of the descending fetal aorta ws 185 ml min-1 kg-1 when based on mean blood velocity, and 261 ml min-1 kg-1 when based on maximum blood velocity. In the intra-abdominal part of the umbilical vein the mean blood flow was 115 ml min-1 kg-1.

Entities:  

Mesh:

Year:  1982        PMID: 7078139     DOI: 10.1016/0141-5425(82)90023-1

Source DB:  PubMed          Journal:  J Biomed Eng        ISSN: 0141-5425


  7 in total

1.  Effect of fetal brainsparing on the early neonatal cerebral circulation.

Authors:  S A Scherjon; H Oosting; J H Kok; H A Zondervan
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  1994-07       Impact factor: 5.747

2.  The umbilical vein in the human fetus has a non-linear growth pattern across gestation.

Authors:  Afrooz Najafzadeh; Peter Jacoby; Eugen Mattes; Jan E Dickinson
Journal:  Australas J Ultrasound Med       Date:  2016-06-23

3.  Fetal circulation 60 to 80 minutes after vaginal prostaglandin E2 in pregnant women at term.

Authors:  A Lindblad; G Ekman; K Marsál; U Ulmsten
Journal:  Arch Gynecol       Date:  1985

4.  Three-dimensional sonographic measurement of blood volume flow in the umbilical cord.

Authors:  Stephen Z Pinter; Jonathan M Rubin; Oliver D Kripfgans; Marjorie C Treadwell; Vivian C Romero; Michael S Richards; Man Zhang; Anne L Hall; J Brian Fowlkes
Journal:  J Ultrasound Med       Date:  2012-12       Impact factor: 2.153

5.  A short history of sonography in obstetrics and gynaecology.

Authors:  S Campbell
Journal:  Facts Views Vis Obgyn       Date:  2013

6.  Operator auditory perception and spectral quantification of umbilical artery Doppler ultrasound signals.

Authors:  Ann Thuring; K Jonas Brännström; Maria Ewerlöf; Edgar Hernandez-Andrade; David Ley; Göran Lingman; Karina Liuba; Karel Maršál; Tomas Jansson
Journal:  PLoS One       Date:  2013-05-20       Impact factor: 3.240

7.  Fetal electrocardiogram (fECG) gated MRI.

Authors:  Martyn N J Paley; Janet E Morris; Debbie Jarvis; Paul D Griffiths
Journal:  Sensors (Basel)       Date:  2013-08-23       Impact factor: 3.576

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.