Literature DB >> 7073903

Extra echo spaces: ultrasonography and computerised tomography correlations.

T Wada, M Honda, S Matsuyama.   

Abstract

Among the echocardiograms of 844 patients of the International Goodwill Hospital from January 1980 to April 1981, 700 showed clinically inexplicable extra echo spaces. Fifty of the 700 had computerised tomography of their hearts which showed the extra echo spaces to be caused either by anterior or posterior subepicardial fat. Six of the 50 cases had both fat and pericardial effusions, which are difficult to differentiate echocardiographically unless follow-up clinical observations are performed. Subepicardial fat deposits are reasonable explanations for the extra echo spaces frequently observed by echocardiography: they correlate well with clinical findings. Subepicardial fat should be recognised as the cause of such extra echo spaces.

Entities:  

Mesh:

Year:  1982        PMID: 7073903      PMCID: PMC481159          DOI: 10.1136/hrt.47.5.430

Source DB:  PubMed          Journal:  Br Heart J        ISSN: 0007-0769


  8 in total

1.  Echocardiography in congenital and acquired absence of the pericardium. An echocardiographic mimic of right ventricular volume overload.

Authors:  M N Payvandi; R E Kerber
Journal:  Circulation       Date:  1976-01       Impact factor: 29.690

2.  PROMINENCE OF THE LEFT EPIPERICARDIAL FAT PAD. A CAUSE OF APPARENT CARDIOMEGALY.

Authors:  D H TUCKER; D H GAYLOR; W J JACOBY; R G SUMNER
Journal:  Am J Med       Date:  1965-02       Impact factor: 4.965

3.  Experimental studies to determine application of CAT scanning to the human body.

Authors:  R J Alfidi; W J MacIntyre; T F Meaney; E S Chernak; P Janicki; R Tarar; H Levin
Journal:  Am J Roentgenol Radium Ther Nucl Med       Date:  1975-06

4.  Sensitivity and specificity of echocardiographic diagnosis of pericardial effusion.

Authors:  M S Horowitz; C S Schultz; E B Stinson; D C Harrison; R L Popp
Journal:  Circulation       Date:  1974-08       Impact factor: 29.690

5.  Newer aspects of echocardiography.

Authors:  H Feigenbaum
Journal:  Circulation       Date:  1973-04       Impact factor: 29.690

6.  Echocardiographic mimicry of pericardial effusion.

Authors:  P C Come; M F Riley; N J Fortuin
Journal:  Am J Cardiol       Date:  1981-02       Impact factor: 2.778

7.  Evaluation of pericardial effusion with computed tomography.

Authors:  H Tomoda; M Hoshiai; H Furuya; Y Oeda; S Matsumoto; T Tanabe; H Tamachi; H Sasamoto; S Koide; S Kuribayashi; S Matsuyama
Journal:  Am Heart J       Date:  1980-06       Impact factor: 4.749

8.  Prolapsed left atrium behind the left ventricular posterior wall: two dimensional echocardiographic and angiographic features.

Authors:  W C Reeves; T Ciotola; J D Babb; E Buonocore; D Leaman
Journal:  Am J Cardiol       Date:  1981-03       Impact factor: 2.778

  8 in total
  1 in total

1.  Illustrative cases in pericardial effusion misdetection: correlation of echocardiography and CT.

Authors:  D Yousem; T T Traill; P S Wheeler; E K Fishman
Journal:  Cardiovasc Intervent Radiol       Date:  1987       Impact factor: 2.740

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.