Bedside ultrasound diagnosis of residual urine volume.

L Henriksson, K Marsál.   

Abstract

A hand-held real-time ultrasound scanner was used for the estimation of bladder volume in the hope of eliminating unnecessary postoperative catheterizations. In 11 women, the bladder was filled stepwise and scans were done at volumes of 0, 50, 100, 150, and 200 ml, 50 ml being chosen as the minimum volume for clinically significant residual urine. The method was then used in 43 examinations on 26 patients, 24 of whom had had a gynecological operation. There were only three mistakes: once a residual urine volume of more than 50 ml was missed, and twice the scan wrongly suggested a residual urine volume of more than 50 ml.

Entities:  

Mesh:

Year:  1982        PMID: 7073335     DOI: 10.1007/bf02111664

Source DB:  PubMed          Journal:  Arch Gynecol        ISSN: 0170-9925


  10 in total

1.  Relationship of bladder shadow to bladder volume on excretion urography.

Authors:  P M BRETLAND
Journal:  J Fac Radiol       Date:  1958-07

2.  A new technique for measurements of the urethra pressure profile.

Authors:  M Asmussen; U Ulmsten
Journal:  Acta Obstet Gynecol Scand       Date:  1976       Impact factor: 3.636

3.  Ultrasonic method of measuring residual urine.

Authors:  O Alfthan; T Mattsson
Journal:  Ann Chir Gynaecol Fenn       Date:  1969

4.  [Determination of residual urine by ultrasonic scanning].

Authors:  J F Pedersen
Journal:  Ugeskr Laeger       Date:  1979-03-05

5.  Determination of organ volume by means of ultrasonic B-mode scanning.

Authors:  B D Doust; J K Baum; N F Maklad; R F Baum
Journal:  J Clin Ultrasound       Date:  1974-06       Impact factor: 0.910

6.  Real time ultrasonic imaging with a hand-held scanner. Part I--technical description.

Authors:  C Ligtvoet; H Rijsterborgh; L Kappen; N Bom
Journal:  Ultrasound Med Biol       Date:  1978       Impact factor: 2.998

7.  [Measurement of the residual urine following hysterectomy by ultra-sonography (author's transl)].

Authors:  W Leucht; E Müller; H Heyes; C Lauritzen
Journal:  Geburtshilfe Frauenheilkd       Date:  1980-12       Impact factor: 2.915

8.  Residual urine determination by ultrasonic scanning.

Authors:  J F Pedersen; R J Bartrum; C Grytter
Journal:  Am J Roentgenol Radium Ther Nucl Med       Date:  1975-10

9.  Ultrasonic studies of the bladder.

Authors:  J H Holmes
Journal:  J Urol       Date:  1967-04       Impact factor: 7.450

10.  Ultrasound assessment of residual urine in children.

Authors:  N W Harrison; C Parks; T Sherwood
Journal:  Br J Urol       Date:  1975
  10 in total
  1 in total

1.  Measurement of residual urine volume using a portable ultrasound instrument.

Authors:  H Fuse; T Yokoyama; Y Muraishi; T Katayama
Journal:  Int Urol Nephrol       Date:  1996       Impact factor: 2.370

  1 in total