A rapid high-performance liquid chromatographic method for quantitation of 5-fluorouracil in plasma after continuous intravenous infusion.

D C Sampson, R M Fox, M H Tattersall, W J Hensley.   

Abstract

A fast, simple, precise, high-performance liquid chromatographic method for the assay of 5-fluorouracil in plasma from humans receiving continuous intravenous infusion is described. After a single extraction, underivatised 5-fluorouracil is assayed by high-performance liquid chromatography using a variable-wavelength ultraviolet detector. After extraction of 1 ml plasma, 0.3 mumol/l can be assayed. The assay is reproducible and linear up to at least 40 mumol/l. A single determination takes 3 hours and a batch of 40 specimens can be extracted and assayed in 4 working hours if automated equipment is used, enabling injections and calculations to be done overnight.

Entities:  

Mesh:

Substances:

Year:  1982        PMID: 7073215     DOI: 10.1177/000456328201900213

Source DB:  PubMed          Journal:  Ann Clin Biochem        ISSN: 0004-5632            Impact factor:   2.057


  1 in total

1.  Effects of the plasma concentration of 5-fluorouracil and the duration of continuous venous infusion of 5-fluorouracil with an inhibitor of 5-fluorouracil degradation on Yoshida sarcomas in rats.

Authors:  S Fujii; Y Shimamoto; H Ohshimo; T Imaoka; M Motoyama; M Fukushima; T Shirasaka
Journal:  Jpn J Cancer Res       Date:  1989-02