Literature DB >> 7066735

A coaxial circle circuit: comparison with conventional circle and Bain circuit.

J Shandro.   

Abstract

A coaxial system to be used for gas delivery to patients in a closed or low fresh gas flow anaesthetic system is described. The resistance to gas flow, humidity of inspired gases, and static compliance of the circuit are provided and compared with the circle tubing customarily employed or the coaxial Mapleson D ("Bain") circuit. The resistance to gas flow is highest in the coaxial circle and "Bain" circuits; the resistance of the conventional circle is approximately 40 per cent less. Static compliance of this coaxial circle is 50 per cent greater than the conventional circle. During artificial ventilation humidity of inspired gases is maintained at levels recommended in the literature for all circuits, but during spontaneous breathing only the conventional rubber circle maintains appropriate levels. Advantages of this coaxial circle over the conventional circle include light weight and small size. Advantages of this coaxial circle over the "Bain" circuit include lower fresh gas flows and improved humidity during spontaneous breathing. These advantages make this coaxial circle useful for routine use.

Entities:  

Mesh:

Substances:

Year:  1982        PMID: 7066735     DOI: 10.1007/bf03007989

Source DB:  PubMed          Journal:  Can Anaesth Soc J        ISSN: 0008-2856


  7 in total

1.  Some physiological effects resulting from added resistance to respiration.

Authors:  C C CAIN; A B OTIS
Journal:  J Aviat Med       Date:  1949-06

2.  The accuracy of the respirometer and ventigrator.

Authors:  J F NUNN; T I EZI-ASHI
Journal:  Br J Anaesth       Date:  1962-07       Impact factor: 9.166

3.  Effects of dry anesthetic gases on tracheobronchial ciliated epithelium.

Authors:  J Chalon; D A Loew; J Malebranche
Journal:  Anesthesiology       Date:  1972-09       Impact factor: 7.892

4.  A safe nonrebreathing system: humidity, sterility, cost.

Authors:  V N Dolorico; J Chalon; D B Weeks; L R Orkin
Journal:  Anesth Analg       Date:  1974 Jan-Feb       Impact factor: 5.108

5.  A study of humidification in tracheostomized dogs.

Authors:  H Noguchi; Y Takumi; O Aochi
Journal:  Br J Anaesth       Date:  1973-08       Impact factor: 9.166

6.  Optimum humidification of air administered to a tracheostomy in dogs. Scanning electron microscopy and surfactant studies.

Authors:  T Tsuda; H Noguchi; Y Takumi; O Aochi
Journal:  Br J Anaesth       Date:  1977-10       Impact factor: 9.166

7.  Humidity in anaesthesiology. 3. Heat and moisture patterns in the respiratory tract during anaesthesia with the semi-closed system.

Authors:  R Déry; J Pelletier; A Jacques; M Clavet; J J Houde
Journal:  Can Anaesth Soc J       Date:  1967-07
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.