Literature DB >> 7059405

Angio-pathological appearances of pulmonary valve in pulmonary atresia with intact ventricular septum. Interpretation of nature of right ventricle from pulmonary angiography.

E A Braunlin, A G Formanek, J H Moller, J E Edwards.   

Abstract

Correlative angiographic-anatomical studies in 19 cases of pulmonary atresia with infarct ventricular septum showed the following relations between the angiographic appearance of the pulmonary valve and the morphology of the right ventricle. (1) Doming of the pulmonary valve was associated with a nearly normal-sized right ventricle and a wide infundibulum patent to the level of the pulmonary valve. (2) A fixed valve was associated either with (a) pronounced hypoplasia of the ventricular changer and stenosis of the infundibulum or (b) less commonly, a massive right ventricle and Ebstein's malformation of the tricuspid valve. (3) An intermediate type valve was associated with a small right ventricle and a small infundibulum which was, however, patent to the level of the pulmonary valve. It is suggested that the configuration of the pulmonary valve is a result of haemodynamic stresses placed upon it. These stresses, in turn, are determined by the morphological nature of the right ventricle. Thus, the nature of the pulmonary valve as seen angiographically may ve used as an index of right ventricular morphology.

Entities:  

Mesh:

Year:  1982        PMID: 7059405      PMCID: PMC481135          DOI: 10.1136/hrt.47.3.281

Source DB:  PubMed          Journal:  Br Heart J        ISSN: 0007-0769


  9 in total

1.  Early and late results in pulmonary atresia.

Authors:  A R Dobell; A Grignon
Journal:  Ann Thorac Surg       Date:  1977-09       Impact factor: 4.330

2.  Two-stage palliative surgical approach for pulmonary atresia with intact ventricular septum (type I).

Authors:  E F Luckstead; L Mattioli; I K Crosby; W A Reed; A M Diehl
Journal:  Am J Cardiol       Date:  1972-04       Impact factor: 2.778

3.  Severe congenital tricuspid incompetence in the neonate.

Authors:  P A Barr; J M Celermajer; J D Bowdler; T B Cartmill
Journal:  Circulation       Date:  1974-05       Impact factor: 29.690

4.  Pathologic spectrum of dysplasia of the tricuspid valve. Features in common with Ebstein's malformation.

Authors:  A E Becker; M J Becker; J E Edwards
Journal:  Arch Pathol       Date:  1971-02

5.  Pulmonary atresia with intact ventricular septum.

Authors:  R B Cole; A J Muster; M Lev; M H Paul
Journal:  Am J Cardiol       Date:  1968-01       Impact factor: 2.778

6.  Pulmonary valvular atresia with intact ventricular septum: problems in diagnosis and results of treatment.

Authors:  S Dhanavaravibul; J J Nora; D G McNamara
Journal:  J Pediatr       Date:  1970-12       Impact factor: 4.406

7.  The tricuspid valve in pulmonary atresia and intact ventricular septum: a morphological study of 60 cases.

Authors:  R M Freedom; M R Dische; R D Rowe
Journal:  Arch Pathol Lab Med       Date:  1978-01       Impact factor: 5.534

8.  Morphological variations in pulmonary atresia with intact ventricular septum.

Authors:  J R Zuberbuhler; R H Anderson
Journal:  Br Heart J       Date:  1979-03

9.  Right ventricular volume determinations in 18 patients with pulmonary atresia and intact ventricular septum. Analysis of factors influencing right ventricular growth.

Authors:  R G Patel; R M Freedom; C A Moes; K R Bloom; P M Olley; W G Williams; G A Trusler; R D Rowe
Journal:  Circulation       Date:  1980-02       Impact factor: 29.690

  9 in total
  3 in total

1.  Changes in the endothelial morphology of the developing semilunar heart valves. A TEM and SEM study in the chick.

Authors:  J M Hurle; E Colvee
Journal:  Anat Embryol (Berl)       Date:  1983

2.  Pulmonary atresia with intact ventricular septum: a quantitative cineventriculographic study of the right and left ventricular function.

Authors:  R Scognamiglio; L Daliento; R Razzolini; G M Boffa; P A Pellegrino; R Chioin; S Dalla Volta
Journal:  Pediatr Cardiol       Date:  1986       Impact factor: 1.655

3.  Comparison of contrast enhanced magnetic resonance angiography with invasive cardiac catheterization for evaluation of children with pulmonary atresia.

Authors:  Soha Romeih; Fathia Al-Sheshtawy; Mai Salama; Nico A Blom; Ahmed Abdel-Razek; Hala Al-Marsafawy; Abdou Elhendy
Journal:  Heart Int       Date:  2012-06-21
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.