| Literature DB >> 7056594 |
Abstract
We found that optimal conditions for the beryllium transformation test required the use of purified lymphocyte suspensions in 20% human serum, with beryllium sulphate at concentrations of 10(-6) to 10(-7) M. Using these conditions, all 15 chronic beryllium patients tested gave a stimulation index of more than 2. Despite the above, 10(-5) and 10(-6)M, BeSO4 inhibited spontaneous thymidine incorporation and lymphocyte transformation to PHA and PPD in normal subjects. Alternative methods, using whole blood, venous and thumb-prick samples, gave fewer and less reproducible positive results.Entities:
Mesh:
Substances:
Year: 1982 PMID: 7056594 DOI: 10.1159/000233010
Source DB: PubMed Journal: Int Arch Allergy Appl Immunol ISSN: 0020-5915