Literature DB >> 7055911

Glucose determinations in plasma and serum: potential error related to increased hematocrit.

R A Sidebottom, P R Williams, K S Kanarek.   

Abstract

This study reports the effect of increased hematocrit (packed cell volume) on the rate of decrease in plasma glucose during 6 h in blood specimens from seven newborns (cord blood) and heparin-treated blood specimens from eight adults. Mean hematocrits ranged frm 0.43 to 0.75 for the adults and from 0.51 to 0.81 for the infants. The decrease in glucose was related to time and to hematocrit. For example, in adults with a mean hematocrit of 0.43, glucose decreased from 890 +/- 40 mg/L to 570 +/- 30 mg/L (mean +/- SEM) at 6 h, whereas in adults with a mean hematocrit of 0.75, glucose decreased from 890 +/- 40 to 200 +/- 30 mg/L. In infants with a mean hematocrit of 0.51, glucose decreased from 1010 +/- 20 to 480 +/- 70 mg/L at 6 h; infants with a mean hematocrit of 0.81 had blood glucose decrease from 1010 +/- 20 to 50 +/- 30 mg/L. These results indicate that the incidence of hypoglycemia in infants with polycythemia may be overestimated, and emphasize the need for prompt handling of blood samples collected from newborns for glucose determinations.

Entities:  

Mesh:

Substances:

Year:  1982        PMID: 7055911

Source DB:  PubMed          Journal:  Clin Chem        ISSN: 0009-9147            Impact factor:   8.327


  4 in total

1.  Uncertainties in the measurement of blood glucose in paediatric intensive care: implications for clinical trials of tight glycaemic control.

Authors:  Helen Hill; Paul Baines; Paul Barton; Paul Newland; Dianne Terlouw; Mark Turner
Journal:  Intensive Care Med       Date:  2011-07-09       Impact factor: 17.440

2.  Accuracy of bedside capillary blood glucose measurements in critically ill patients.

Authors:  C Dana Critchell; Vincent Savarese; Amy Callahan; Christine Aboud; Serge Jabbour; Paul Marik
Journal:  Intensive Care Med       Date:  2007-09-01       Impact factor: 17.440

3.  Comment on "System accuracy evaluation of the GlucoRx Nexus Voice TD-4280 blood glucose monitoring system".

Authors:  Nilesh Nathwani
Journal:  Dis Markers       Date:  2015-03-17       Impact factor: 3.434

4.  Effects of Sampling and Storage Method on Chicken Blood Glucose Measurement.

Authors:  Takeshi Kawasaki; Tomohito Iwasaki; Itsuki Ohya; Yasuhiro Hasegawa; Mitsuo Noguchi; Takafumi Watanabe
Journal:  J Poult Sci       Date:  2020-07-25       Impact factor: 1.425