Literature DB >> 7055425

Real-time Doppler spectrum analysis: predictive value in defining operable carotid artery disease.

R W Barnes, S E Rittgers, W W Putney.   

Abstract

A prospective study compared the sensitivity, specificity, and predictive value of indirect periorbital Doppler screening and direct carotid Doppler interrogation using real-time sound spectrum analysis to detect operable extracranial carotid occlusive disease. The results of noninvasive studies were compared with independently assessed contrast arteriograms of carotid arteries of patients studied for symptomatic cerebrovascular disease. Periorbital Doppler ultrasound was insensitive to carotid stenosis of less than 75% and did not distinguish operable stenosis from inoperable occlusion of the internal carotid artery. Carotid Doppler spectrum analysis was sensitive to 98% of hemodynamically significant disease and correctly discriminated 77% of carotid occlusions, 96% of stenoses larger than 50%, and 70% of stenoses of less than 50%. The predictive value for direct carotid interrogation in identifying carotid occlusion or operable stenosis was 94% and 86%, respectively. Real-time spectrum analysis of direct carotid Doppler signals substantially improves the diagnostic accuracy of noninvasive identification of operable carotid artery disease.

Entities:  

Mesh:

Year:  1982        PMID: 7055425     DOI: 10.1001/archsurg.1982.01380250034008

Source DB:  PubMed          Journal:  Arch Surg        ISSN: 0004-0010


  5 in total

1.  Predictive value of cervical bruit for the detection of obstructive lesions of the internal carotid artery. Data from 2000 patients.

Authors:  M Floriani; S M Giulini; G P Anzola; S Bonardelii; N Portolani; M P Pasolini; G Tiberio
Journal:  Ital J Neurol Sci       Date:  1989-06

2.  Can clinical evaluation and noninvasive testing substitute for arteriography in the evaluation of carotid artery disease?

Authors:  W S Moore; S Ziomek; W J Quiñones-Baldrich; H I Machleder; R W Busuttil; J D Baker
Journal:  Ann Surg       Date:  1988-07       Impact factor: 12.969

3.  Continuous-wave versus range-gated pulsed Doppler power frequency spectrum analysis in the detection of carotid arterial occlusive disease.

Authors:  T R Harward; E F Bernstein; A Fronek
Journal:  Ann Surg       Date:  1986-07       Impact factor: 12.969

4.  Noninvasive assessment of carotid artery disease.

Authors:  R W Barnes
Journal:  West J Med       Date:  1983-10

Review 5.  Duplex ultrasound for diagnosing symptomatic carotid stenosis in the extracranial segments.

Authors:  Nicolle Cassola; Jose Cc Baptista-Silva; Luis Cu Nakano; Carolina Dq Flumignan; Ricardo Sesso; Vladimir Vasconcelos; Nelson Carvas Junior; Ronald Lg Flumignan
Journal:  Cochrane Database Syst Rev       Date:  2022-07-11
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.