Literature DB >> 7053603

Role of implantable pacemakers in control of recurrent ventricular tachycardia.

J D Fisher, S G Kim, S Furman, J A Matos.   

Abstract

Implanted pacemakers can provide a viable alternative to pharmacologic therapy or surgical management of patients with recurrent ventricular tachycardia. An increasing variety of pacemaker techniques are proving useful for preventing, controlling the effective rate of or terminating ventricular tachycardia. To assess the role of permanent pacing in the treatment of ventricular tachycardia, a consecutive series of 160 patients undergoing electrophysiologic testing for recurrent ventricular tachycardia were analyzed. Thirty-nine patients received implantable pacemakers, of which 13 were intended for bursts of rapid ventricular pacing. No adverse responses were attributed to these burst pacemakers, but concern for possible acceleration of tachycardia and appropriate identification of the arrhythmia were among factors limiting more widespread use of antitachycardia pacing. Some of these limitations may be resolved with further advances in electrophysiologic understanding of arrhythmias combined with strides in medical electronics, which will permit the development of new generations of highly sophisticated antitachycardia pacemakers.

Entities:  

Mesh:

Year:  1982        PMID: 7053603     DOI: 10.1016/0002-9149(82)90294-6

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  4 in total

Review 1.  Role of substrate and triggers in the genesis of cardiac alternans, from the myocyte to the whole heart: implications for therapy.

Authors:  Faisal M Merchant; Antonis A Armoundas
Journal:  Circulation       Date:  2012-01-24       Impact factor: 29.690

2.  Recent trends in the management of life-threatening ventricular arrhythmias.

Authors:  B N Singh; J N Weiss; K Nademanee; J H Wittig; P Guzy
Journal:  West J Med       Date:  1984-11

3.  Profound independent effects of left bundle branch block and heart rate during supraventricular tachycardia.

Authors:  John D Fisher
Journal:  J Interv Card Electrophysiol       Date:  2005-04       Impact factor: 1.900

4.  Efficacy of a tiered therapy defibrillator system used to treat recurrent ventricular arrhythmias refractory to drugs.

Authors:  A C Rankin; S Zaim; A Powell; B Zaim; R Brooks; B A McGovern; H Garan; J N Ruskin
Journal:  Br Heart J       Date:  1993-07
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.