Literature DB >> 7034254

Clinical biochemistry of tears.

N J Van Haeringen.   

Abstract

The composition of tear fluid as it exists in the conjunctival fornix and in the precorneal tear film is of a complicated nature. The precorneal tear film is a physically inhomogenous system, produced by the lacrimal glands, the accessory lacrimal glands and the goblet cells of the conjunctiva and the Meibomian glands of the lid margin. The method of collection is crucial for the quantity and concentration of a great number of different compounds that have been demonstrated in tears. A survey is given of the literature concerning tears as they are composed of proteins, enzymes, lipids, metabolites, electrolytes and drugs, the latter secreted during therapy. Clinical applications of the determination of several compounds for diagnosis or for monitoring drug therapy are summarized.

Entities:  

Mesh:

Substances:

Year:  1981        PMID: 7034254     DOI: 10.1016/0039-6257(81)90145-4

Source DB:  PubMed          Journal:  Surv Ophthalmol        ISSN: 0039-6257            Impact factor:   6.048


  68 in total

1.  Ophthalmic glucose sensing: a novel monosaccharide sensing disposable and colorless contact lens.

Authors:  Ramachandram Badugu; Joseph R Lakowicz; Chris D Geddes
Journal:  Analyst       Date:  2004-05-10       Impact factor: 4.616

Review 2.  Ophthalmic glucose monitoring using disposable contact lenses--a review.

Authors:  Ramachandram Badugu; Joseph R Lakowicz; Chris D Geddes
Journal:  J Fluoresc       Date:  2004-09       Impact factor: 2.217

3.  Defensins and other antimicrobial peptides at the ocular surface.

Authors:  Alison M McDermott
Journal:  Ocul Surf       Date:  2004-10       Impact factor: 5.033

4.  Dry eye and designer ophthalmics.

Authors:  Gordon W Laurie; Leslie A Olsakovsky; Brian P Conway; Robert L McKown; Kazuko Kitagawa; Jason J Nichols
Journal:  Optom Vis Sci       Date:  2008-08       Impact factor: 1.973

5.  Extensive characterization of human tear fluid collected using different techniques unravels the presence of novel lipid amphiphiles.

Authors:  Sin Man Lam; Louis Tong; Xinrui Duan; Andrea Petznick; Markus R Wenk; Guanghou Shui
Journal:  J Lipid Res       Date:  2013-11-28       Impact factor: 5.922

Review 6.  Noninvasive diagnostic devices for diabetes through measuring tear glucose.

Authors:  Jin Zhang; William Hodge; Cindy Hutnick; Xianbin Wang
Journal:  J Diabetes Sci Technol       Date:  2011-01-01

Review 7.  Aging and the lacrimal system.

Authors:  N J Van Haeringen
Journal:  Br J Ophthalmol       Date:  1997-10       Impact factor: 4.638

8.  CA 19-9 ELISA test: a new method for studying mucus changes in tears.

Authors:  C Garcher; A Bron; C Baudouin; L Bildstein; J Bara
Journal:  Br J Ophthalmol       Date:  1998-01       Impact factor: 4.638

9.  Niosome-encapsulated gentamicin for ophthalmic controlled delivery.

Authors:  Ghada Abdelbary; Nashwa El-Gendy
Journal:  AAPS PharmSciTech       Date:  2008-06-18       Impact factor: 3.246

10.  A three-phase in-vitro system for studying Pseudomonas aeruginosa adhesion and biofilm formation upon hydrogel contact lenses.

Authors:  Claudia Rändler; Rutger Matthes; Andrew J McBain; Bernd Giese; Martin Fraunholz; Rabea Sietmann; Thomas Kohlmann; Nils-Olaf Hübner; Axel Kramer
Journal:  BMC Microbiol       Date:  2010-11-09       Impact factor: 3.605

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.