Use of microporous expanded polytetrafluoroethylene grafts for aorta-pulmonary shunts in infants with complex cyanotic heart disease. A report of seven cases.

R B Jennings, B J Innes, R D Brickman.   

Abstract

Seven cyanotic infants in our institution have undergone central aorta--pulmonary artery shunt operations with a microporous expanded polytetrafluoroethlene (PTFE) graft. All of these patients have had pulmonary atresia, in four cases associated with endocardial cushion type defects. Four patients have had excellent palliation for up to 13 months. Congestive heart failure and kinking of the pulmonary artery, frequently seen with other types of central aorta-pulmonary shunts, have not been a problem. Until further experience is gained with this procedure, however, we reserve its use to the occasional cyanotic infant in whom neither open-heart repair or the Blalock-Taussig shunt is feasible.

Entities:  

Mesh:

Substances:

Year:  1978        PMID: 703356

Source DB:  PubMed          Journal:  J Thorac Cardiovasc Surg        ISSN: 0022-5223            Impact factor:   5.209


  5 in total

1.  Computational fluid dynamics characterization of blood flow in central aorta to pulmonary artery connections: importance of shunt angulation as a determinant of shear stress-induced thrombosis.

Authors:  Carey Celestin; Martin Guillot; Nancy Ross-Ascuitto; Robert Ascuitto
Journal:  Pediatr Cardiol       Date:  2014-11-18       Impact factor: 1.655

2.  Use of saphenous vein allografts for aortopulmonary artery anastomoses in neonates with complex cyanotic congenital heart disease.

Authors:  D Danilowicz; R G Ishmael; E F Doyle; O W Isom; S B Colvin; M A Greco
Journal:  Pediatr Cardiol       Date:  1984 Jan-Mar       Impact factor: 1.655

3.  Preliminary experience with GORE-TEX grafting for right ventricle-pulmonary artery conduits.

Authors:  J E Molina
Journal:  Tex Heart Inst J       Date:  1986-03

4.  Experience with the modified Blalock-Taussig operation using polytetrafluoroethylene (Impra) grafts.

Authors:  P H Kay; A Capuani; R Franks; C Lincoln
Journal:  Br Heart J       Date:  1983-04

5.  Septic involvement of polytetrafluoroethylene (PTFE) anastomoses producing false aneurysms: diagnosis and problems related to management.

Authors:  C N Monarrez; R F Montalvo; V R Conti; D W Sapire
Journal:  Pediatr Cardiol       Date:  1984       Impact factor: 1.655