Literature DB >> 7032014

Monocyte-mediated erythrocyte destruction. A comparative study of current methods.

J S Hunt, M L Beck, G W Wood.   

Abstract

Three assay systems-EAIgG rosette formation, 51Cr release, and erythrophagocytosis-were used to quantitate interaction between antibody-coated human erythrocytes and normal blood monocytes. The three methods were compared in terms of time requirements and sensitivity. Erythrophagocytosis required more time to perform (2 hours) than did rosette tests (30 minutes) but less than minimum 51Cr release assays (5.5 hours). Erythrophagocytosis was 20-fold more sensitive than either of the other two procedures. Results obtained with purified IgG anti-D and with antibodies induced by transfusion or pregnancy were similar.

Entities:  

Mesh:

Substances:

Year:  1981        PMID: 7032014     DOI: 10.1046/j.1537-2995.1981.21682085766.x

Source DB:  PubMed          Journal:  Transfusion        ISSN: 0041-1132            Impact factor:   3.157


  2 in total

1.  Use of a Monocyte Monolayer Assay to Evaluate Fcγ Receptor-mediated Phagocytosis.

Authors:  Tik Nga Tong; Donald R Branch
Journal:  J Vis Exp       Date:  2017-01-02       Impact factor: 1.355

2.  18F-fluorodeoxyglucose positron emission tomography-computed tomography for assessing organ distribution of stressed red blood cells in mice.

Authors:  Wen-Yu Yin; Jiao Yuan; Zhi-Min Zhang; Cheng Mei; Wei Xu; Yong-Xiang Tang; Fang Peng; Ning Li
Journal:  Sci Rep       Date:  2021-01-28       Impact factor: 4.379

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.