An evaluation of thermodilution cardiac output measurement using the Swan-Ganz catheter.

W B Runciman, A H Ilsley, J G Roberts.   

Abstract

Errors in thermodilution cardiac output measurement were quantitated to determine the order of accuracy of routine measurements performed by unskilled personnel. In vitro and in vivo studies were undertaken to examine factors affecting the volume and temperature of the injectate, catheter thermistor and computer performance, effect of respiration, use of cold (0-4 degrees C) versus ambient temperature (20-25 degrees C) injectate, and the interpretation of measurements. Ambient temperature injectate incurred unacceptably large errors; cold injectate (injections were timed with respiration) produced variations in performance by equipment and personnel which accounted for only 2% of the variation between successive measurements. Real changes in cardiac output and inherent variability of the downslope of the thermal curve, necessitating an empirically based calculation, account for up to 10% variation between successive measurements. When cold injectate was used, and the average of three corrected measurements taken, thermodilution cardiac output measurements were within 10% of a simultaneous dye dilution measurement.

Mesh:

Year:  1981        PMID: 7025698     DOI: 10.1177/0310057X8100900302

Source DB:  PubMed          Journal:  Anaesth Intensive Care        ISSN: 0310-057X            Impact factor:   1.669


  7 in total

1.  Thermodilution cardiac output measurement with a large left-to-right shunt.

Authors:  R G Pearl; L C Siegel
Journal:  J Clin Monit       Date:  1991-04

Review 2.  Cardiac output measurements. A review of current techniques and research.

Authors:  K C Ehlers; K C Mylrea; C K Waterson; J M Calkins
Journal:  Ann Biomed Eng       Date:  1986       Impact factor: 3.934

3.  Residual pulmonary vasoreactivity to inhaled nitric oxide in patients with severe obstructive pulmonary hypertension and Eisenmenger syndrome.

Authors:  W Budts; N Van Pelt; H Gillyns; M Gewillig; F Van De Werf; S Janssens
Journal:  Heart       Date:  2001-11       Impact factor: 5.994

4.  Investigation of a continuous heating/cooling technique for cardiac output measurement.

Authors:  K C Ehlers; K C Mylrea; J M Calkins
Journal:  Ann Biomed Eng       Date:  1987       Impact factor: 3.934

Review 5.  Errors in the measurement of cardiac output by thermodilution.

Authors:  T Nishikawa; S Dohi
Journal:  Can J Anaesth       Date:  1993-02       Impact factor: 5.063

6.  Hepatic blood flow during reduced liver grafting in pigs. A comparison of controls and recipients of intact allografts.

Authors:  R Hickman; G N Stapleton; B Mets; S Hlatshwayo; P Janicki
Journal:  Dig Dis Sci       Date:  1995-06       Impact factor: 3.199

7.  Effect of contrast material injection duration on arterial enhancement at CT in patients with various cardiac indices: Analysis using computer simulation.

Authors:  Toru Higaki; Takeshi Nakaura; Masafumi Kidoh; Hideaki Yuki; Yasuyuki Yamashita; Yuko Nakamura; Fuminari Tatsugami; Yasutaka Baba; Makoto Iida; Kazuo Awai
Journal:  PLoS One       Date:  2018-02-23       Impact factor: 3.240

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.