S Salmassi, M M Yokoyama, J A Maples, Y Matsui.
Abstract
Paraformaldehyde-fixed platelets from normal donors were used for detection of antibody to platelet by in vitro sensitization (indirect method) utilizing rabbit anti-human IgG heavy chain specific antibody-coated polyacrylamide gels (Immunobeads). The sensitized platelets formed rosettes with Immunobeads and the positive rosette count was over 30%, while control showed less than 8% when normal sera were used. This method was also applicable for detecting antibody-sensitized platelets in vivo (direct method) in patients with autoimmune thrombocytopenia. This method is simple, rapid and reproducible for clinical use. Direct and indirect immunofluorescent antibody tests and a blocking test with anti-human serum also supported the results of Immunobead rosetting technique.Entities:
Mesh:
Substances:
Year: 1980 PMID: 7020240 DOI: 10.1111/j.1423-0410.1980.tb01869.x
Source DB: PubMed Journal: Vox Sang ISSN: 0042-9007 Impact factor: 2.144