Literature DB >> 7017109

Posterior peripheral seal distortion related to processing temperature.

D N Firtell, A J Green, J M Elahi.   

Abstract

A conventional acrylic resin was processed at temperatures varying from 135 degrees F to 180 degrees F. No significant distortion in the posterior peripheral seal of a denture base was noted when the material was processed at or below the manufacturer's recommended temperature. Statistically significant distortion was noted in the posterior peripheral seal of a denture base when processing was done above the recommended temperature. An acrylic resin specially designed to be boiled produced significantly less distortion in a denture base than the conventional acrylic resin.

Mesh:

Substances:

Year:  1981        PMID: 7017109     DOI: 10.1016/0022-3913(81)90418-2

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  6 in total

1.  CAD/CAM milled removable complete dentures: an in vitro evaluation of trueness.

Authors:  Murali Srinivasan; Yoann Cantin; Albert Mehl; Harald Gjengedal; Frauke Müller; Martin Schimmel
Journal:  Clin Oral Investig       Date:  2016-11-08       Impact factor: 3.573

2.  A comparative evaluation of the dimensional accuracy of heat polymerised PMMA denture base cured by different curing cycles and clamped by R S technique and conventional method - An In-vitro study.

Authors:  Mandava Ramesh Babu; C Satyanageswar Rao; Syed Tauqheer Ahmed; J S V Bharat; N Venugopal Rao; V Vinod
Journal:  J Int Oral Health       Date:  2014-04-26

3.  Comparison of cooling methods on denture base adaptation of rapid heat-cured acrylic using a three-dimensional superimposition technique.

Authors:  Lee Wei May; Jacob John; Lim Ghee Seong; Zubaidah Zanul Abidin; Norliza Ibrahim; Mahmoud Danaee; Noorhayati Raja Mohd
Journal:  J Indian Prosthodont Soc       Date:  2021 Apr-Jun

4.  Impact Strength and Dimensional Accuracy of Heat-Cure Denture Base Resin Reinforced With ZrO2 Nanoparticles: An In Vitro Study.

Authors:  S Sajida Begum; R Ajay; V Devaki; Krishnamoorthi Divya; K Balu; P Arun Kumar
Journal:  J Pharm Bioallied Sci       Date:  2019-05

5.  Effect of flask closure method and post-pressing time on the displacement of maxillary denture teeth.

Authors:  Wagner A Negreiros; Rafael L X Consani; Marcelo F Mesquita; Mario A C Sinhoreti; Ivan R Faria
Journal:  Open Dent J       Date:  2009-03-06

6.  A study of correlation between posterior palatal seal width and soft palatal angulation with palatal contour.

Authors:  Rupal J Shah; Sanjay B Lagdive; Divyeshkumar B Modi; Bhavyata Darji; Vedanshi A Amin; Ghanshyambhai C Patel
Journal:  J Indian Prosthodont Soc       Date:  2016 Apr-Jun
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.