Literature DB >> 7016436

Precision and accuracy: concepts and assessment by method evaluation testing.

J O Westgard.   

Abstract

Achieving precision and accuracy in routine clinical analyses is a complex task, requiring the identification, estimation, and elimination of sources of analytical error. This review first considers concepts of precision and accuracy, including discussions of the meaning of measurement process, analytical method, state of statistical control, precision, imprecision, accuracy, inaccuracy, systematic error, overall or total error, true value, traceability, and compatability. These concepts provide the basis upon which the performance of analytical methods can be evaluated. The second part of the review considers how precision and accuracy are assessed by the use of method evaluation experiments. The approach emphasizes the development of an evaluation protocol based on the analytical characteristics which represent the performance of the method. This includes discussions of the familiarization period; testing analytic range and linearity; testing precision by a replication experiment; testing accuracy by recovery, interference, and comparison of methods experiments; the selection of a comparative analytical method; the statistical analysis of method comparison data, including the interpretation of that data; the collaborative testing.

Mesh:

Substances:

Year:  1981        PMID: 7016436     DOI: 10.3109/10408368109106450

Source DB:  PubMed          Journal:  Crit Rev Clin Lab Sci        ISSN: 1040-8363            Impact factor:   6.250


  6 in total

Review 1.  Laboratory methods for allergen extract analysis and quality control.

Authors:  T J Grier
Journal:  Clin Rev Allergy Immunol       Date:  2001-10       Impact factor: 8.667

2.  Evolution of a national urine quality assurance programme: the Australasian experience, 1981-1983.

Authors:  M D Shephard; L A Penberthy; C G Fraser
Journal:  J Clin Pathol       Date:  1984-04       Impact factor: 3.411

3.  Use of Deming regression in method-comparison studies.

Authors:  H Konings
Journal:  Surv Immunol Res       Date:  1982

4.  Comparison of different sample preparation methods for platinum determination in cultured cells by graphite furnace atomic absorption spectrometry.

Authors:  Man Xiao; Zaiju Huang; Jing Cai; Jinghui Jia; Yuzeng Zhang; Weihong Dong; Zehua Wang
Journal:  PeerJ       Date:  2017-01-18       Impact factor: 2.984

5.  Contribution of Cervical Proprioception, Vision, and Vestibular Feedback on Reducing Dynamic Head-Trunk Orientation Error in the Yaw Direction.

Authors:  Rami Mooti; Hangue Park
Journal:  Front Neurosci       Date:  2022-01-24       Impact factor: 4.677

6.  Verification of quantitative analytical methods in medical laboratories.

Authors:  Ghafar Muhammad T Abdel; Muhammad I El-Masry
Journal:  J Med Biochem       Date:  2021-06-05       Impact factor: 3.402

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.