Literature DB >> 7016373

Fluorescence polarization immunoassay. II. Analyzer for rapid, precise measurement of fluorescence polarization with use of disposable cuvettes.

S R Popelka, D M Miller, J T Holen, D M Kelso.   

Abstract

This instrument, developed for quantitating fluorescence polarization immunoassays, automatically measures both polarization components and computes a polarization value corrected for background and optical bias. An electronically switched liquid crystal provides a nonmechanical means of rotating the plane of polarization in the excitation optics. The electronic design features digital integration and microprocessor controlled functions. Readings are made in disposable 12 X 75 mm round culture tubes. in less than 10 s. Results are precise to 0.001 polarization unit, linear from 10(-7) to 10(-10) mol of fluorescein per liter, and correlate well with those obtained with other "high-performance" instrumentation.

Entities:  

Mesh:

Substances:

Year:  1981        PMID: 7016373

Source DB:  PubMed          Journal:  Clin Chem        ISSN: 0009-9147            Impact factor:   8.327


  7 in total

Review 1.  Fluorescence polarization/anisotropy in diagnostics and imaging.

Authors:  David M Jameson; Justin A Ross
Journal:  Chem Rev       Date:  2010-05-12       Impact factor: 60.622

2.  Clinical chemistry through Clinical Chemistry: a journal timeline.

Authors:  Robert Rej
Journal:  Clin Chem       Date:  2004-12       Impact factor: 8.327

3.  Analysis of free drug fractions using near-infrared fluorescent labels and an ultrafast immunoextraction/displacement assay.

Authors:  Corey M Ohnmacht; John E Schiel; David S Hage
Journal:  Anal Chem       Date:  2006-11-01       Impact factor: 6.986

4.  Homogeneous immunoassays.

Authors:  R C Boguslaski; T M Li
Journal:  Appl Biochem Biotechnol       Date:  1982-09       Impact factor: 2.926

5.  Abbott's fluorescence polarization immunoassay for cyclosporine and metabolites compared with the Sandoz "Sandimmune" RIA.

Authors:  A Sanghvi; W Diven; H Seltman; T Starzl
Journal:  Clin Chem       Date:  1988-09       Impact factor: 8.327

6.  Automated fluorescence polarization immunoassay for monitoring streptomycin.

Authors:  K S Schwenzer; J P Anhalt
Journal:  Antimicrob Agents Chemother       Date:  1983-05       Impact factor: 5.191

7.  Ocular availability of gentamicin in small animals after topical administration of a conventional eye drop solution and a novel long acting bioadhesive ophthalmic drug insert.

Authors:  F Gurtler; V Kaltsatos; B Boisramé; J Deleforge; M Gex-Fabry; L P Balant; R Gurny
Journal:  Pharm Res       Date:  1995-11       Impact factor: 4.200

  7 in total