Literature DB >> 701505

Standardization of computed tomography images by means of a material-selective beam hardening correction.

P Rüegsegger, T Hangartner, H U Keller, T Hinderling.   

Abstract

Polychromaticity of the X-rays used in computed tomography (CT) has made it difficult to establish an absolute scale for CT values and has made quantitative comparisons between patients unreliable. The spectral shift of the X-rays depends on the material distribution within the structure measured and is significant if substantial amounts of bone, fat, or injected contrast material are present. A material-selective beam hardening correction procedure has been developed that allows the reconstruction of good approximations of linear attenuation coefficients with respect to a reference energy. With the aid of mathematical simulations and measurements on a physical phantom, the feasibility of the procedure and its insensitivity with regard to energy settings and other machine parameters are documented.

Entities:  

Mesh:

Year:  1978        PMID: 701505     DOI: 10.1097/00004728-197804000-00012

Source DB:  PubMed          Journal:  J Comput Assist Tomogr        ISSN: 0363-8715            Impact factor:   1.826


  7 in total

1.  Achieving accurate radiochromic optical-CT imaging when using a polychromatic light source.

Authors:  A Thomas; M Pierquet; M Oldham
Journal:  J Phys Conf Ser       Date:  2010

2.  Non-convexly constrained image reconstruction from nonlinear tomographic X-ray measurements.

Authors:  Thomas Blumensath; Richard Boardman
Journal:  Philos Trans A Math Phys Eng Sci       Date:  2015-06-13       Impact factor: 4.226

3.  A method to correct for spectral artifacts in optical-CT dosimetry.

Authors:  Andrew Thomas; Michael Pierquet; Kevin Jordan; Mark Oldham
Journal:  Phys Med Biol       Date:  2011-05-13       Impact factor: 3.609

4.  The dynamic spatial reconstructor: a computed tomography system for high-speed simultaneous scanning of multiple cross sections of the heart.

Authors:  R A Robb; A H Lent; B K Gilbert; A Chu
Journal:  J Med Syst       Date:  1980       Impact factor: 4.460

5.  Loss and recovery of trabecular bone in the distal radius following fracture--immobilization of the upper limb in children.

Authors:  U Elsasser; P Rüegsegger; M Anliker; G U Exner; A Prader
Journal:  Klin Wochenschr       Date:  1979-08-01

6.  Comparison of automated beam hardening correction (ABHC) algorithms for myocardial perfusion imaging using computed tomography.

Authors:  Jacob Levi; Hao Wu; Brendan L Eck; Rachid Fahmi; Mani Vembar; Amar Dhanantwar; Anas Fares; Hiram G Bezerra; David L Wilson
Journal:  Med Phys       Date:  2020-12-07       Impact factor: 4.506

7.  Calibration-free beam hardening correction for myocardial perfusion imaging using CT.

Authors:  Jacob Levi; Brendan L Eck; Rachid Fahmi; Hao Wu; Mani Vembar; Amar Dhanantwari; Anas Fares; Hiram G Bezerra; David L Wilson
Journal:  Med Phys       Date:  2019-03-07       Impact factor: 4.071

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.