Literature DB >> 7014814

Prospective clinical comparison of two methods for mechanical ventilation of neonates: rapid rate and short inspiratory time versus slow rate and long inspiratory time.

D A Heicher, D S Kasting, J R Harrod.   

Abstract

A prospective comparison was made of the clinical courses of two groups of neonates ventilated according to different protocols: one group at rates of 20 to 40/minute with a one-second IT, and the other at a rate of 60/minute and 0.5 second IT. Other ventilator settings were adjusted within protocol limits to maintain desired blood gas values. Mean starting and highest PIP were lower in the rapid rate group. The results showed no difference in mortality, failure to remain within protocol limits, time requiring respiratory treatment or FiO2 more than 0.6, and incidence of PDA or chronic lung disease. There was a difference (P = 0.011) in number of infants developing pneumothoraces (14% in the rapid group vs 35% in the slow group). Rapid rate ventilation can be used to decrease the incidence of pneumothorax, reserving long IT and higher PIP for infants who cannot be oxygenated or ventilated without them.

Entities:  

Mesh:

Year:  1981        PMID: 7014814     DOI: 10.1016/s0022-3476(81)80604-x

Source DB:  PubMed          Journal:  J Pediatr        ISSN: 0022-3476            Impact factor:   4.406


  23 in total

Review 1.  Bronchopulmonary dysplasia: early diagnosis, prophylaxis, and treatment.

Authors:  A Greenough
Journal:  Arch Dis Child       Date:  1990-10       Impact factor: 3.791

2.  A multicenter randomized controlled clinical trial of bovine surfactant for prevention of respiratory distress syndrome.

Authors:  L Gortner; U Bernsau; H H Hellwege; G Hieronimi; G Jorch; H L Reiter
Journal:  Lung       Date:  1990       Impact factor: 2.584

Review 3.  High frequency positive pressure ventilation in neonates.

Authors:  A D Milner; E W Hoskyns
Journal:  Arch Dis Child       Date:  1989-01       Impact factor: 3.791

4.  Randomised controlled trial of two methods of weaning from high frequency positive pressure ventilation.

Authors:  A Greenough; J Pool; H Gamsu
Journal:  Arch Dis Child       Date:  1989-06       Impact factor: 3.791

5.  [Indirect determination of the intrapulmonary pressure course in the lung model in high frequency ventilation].

Authors:  W Hultzsch; G Lipowsky
Journal:  Klin Wochenschr       Date:  1989-09-15

6.  The effect of a manometer on the mean airway pressure during hand ventilation, an in vitro study.

Authors:  J Karsdon; T Stijnen; H M Berger
Journal:  Eur J Pediatr       Date:  1989-04       Impact factor: 3.183

7.  Synchronous mechanical ventilation of the neonate.

Authors:  M South; C J Morley
Journal:  Arch Dis Child       Date:  1986-12       Impact factor: 3.791

8.  Factors associated with neonatal deaths in very low birth weight infants.

Authors:  T A Clarke; P J McKenna; T G Matthews
Journal:  Ir J Med Sci       Date:  1987-07       Impact factor: 1.568

9.  Lack of association between barotrauma and air leak in hyaline membrane disease.

Authors:  W O Tarnow-Mordi; A Narang; A R Wilkinson
Journal:  Arch Dis Child       Date:  1985-06       Impact factor: 3.791

10.  High frequency ventilation in the neonatal period.

Authors:  A Greenough; A D Milner
Journal:  Eur J Pediatr       Date:  1987-09       Impact factor: 3.183

View more