Clinical evaluation of high-frequency positive-pressure ventilation (HFPPV) in patients scheduled for open-chest surgery.

J R Malina, S G Nordström, U H Sjöstrand, L M Wattwil.   

Abstract

Comparisons were made in 10 patients scheduled for thoracotomy between a prototype of a low-compressive system (Bronchovent Special) for volume-controlled, high-frequency positive-pressure ventilation (HFPPV; fixed frequency of 60/min; fixed relative insufflation time of 22%), and a conventional respirator (SV-900) for intermittent positive-pressure, volume-controlled ventilation at a frequency of 20/min, after induction of anesthesia, but before surgery. With both ventilator systems intratracheal, intrapleural, systolic, diastolic, and mean arterial systemic and central venous pressures were measured at normoventilation (normocarbia). Mean intratracheal pressure and mean intrapleural pressure were significantly lower with volume-controlled HFPPV (1.3 +/- 0.5 and -4.0 +/- 2.1 (SD) cm H2O, respectively) than with conventional volume-controlled ventilation with SV-900 (2.1 +/- 1.2 and -3.0 +/- 1.5 cm H2O, respectively). No significant differences between the two ventilators were found with respect to arterial systemic and central venous pressures, arterial oxygen and carbon dioxide tensions, or alveolar-arterial oxygen tension difference. With the thorax open, during volume-controlled HFPPV the exposed lung was moderately expanded and exhibited only minor movements during insufflation. Repeated blood gas analyses during surgery showed normocarbia and good oxygenation even during compression of the exposed lung. After compression the lung was readily re-expanded with the aid of a brief period of positive end-expiratory pressure (PEEP). Thus, even relatively low intrapulmonary pressures during volume-controlled HFPPV without PEEP are adequate to keep the open-chest lung expanded during intrathoracic surgery. This creates optimal conditions for the surgeons.

Entities:  

Mesh:

Year:  1981        PMID: 7013568

Source DB:  PubMed          Journal:  Anesth Analg        ISSN: 0003-2999            Impact factor:   5.108


  2 in total

1.  Treatment of hypoxemia during esophagectomy by high frequency jet ventilation.

Authors:  K Tsuno; Y Sakanashi; M Matsumoto; Y Kakiuchi; H Miyazaki
Journal:  J Anesth       Date:  1990-07       Impact factor: 2.078

2.  Transthoracic resection of esophageal cancer in patients with pulmonary dysfunction. Usefulness of high frequency ventilation during thoracotomy.

Authors:  M Imamura; K Yanagibashi; T Tobe; Y Shimada; M Naito; T Arai; Y Hatano
Journal:  Ann Surg       Date:  1988-11       Impact factor: 12.969

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.