Literature DB >> 7009638

Quantitative fluorescent immunoassay for measurement of antibody to Dirofilaria immitis in dogs.

H J Gittelman, R B Grieve, M M Hitchings, R H Jacobson, R H Cypess.   

Abstract

An automated fluorescent immunoassay technique (FIAX; International Diagnostic Technology, Santa Clara, Calif.) has been developed for the quantitation of circulating antibodies in dogs infected with Dirofilaria immitis. Two groups of sera, group I consisting of 77 samples and group II consisting of 126 samples, were obtained from experimentally infected microfilaremic dogs, known negative controls, and clinically diagnosed cases of occult dirofilariasis. Antibody against a partially purified trichloroacetic acid-soluble extract of a soluble somatic extract of D. immitis was measured by FIAX and by an enzyme-linked immunosorbent assay (ELISA). A standard curve was drawn from four samples with known FIAX titers and fluorescent signal unit values. The standard curve was used to determine titers of unknown samples. The correlation coefficients determined in the analysis of log10 ELISA and log10 FIAX values were r = 0.9057 and r = 0.8976 in groups I and II, respectively. Eighty-three percent of the titer values calculated by FIAX in group I were within one dilution, and 95% were within two dilutions, of those titers obtained by ELISA. In group II, 79 and 96% of the values obtained by FIAX were within one and two dilutions, respectively, of those obtained by ELISA. FIAX proved to be a reproducible and convenient assay for the measurement of serum antibody in dogs experimentally infected with Dirofilaria.

Entities:  

Mesh:

Substances:

Year:  1981        PMID: 7009638      PMCID: PMC273782          DOI: 10.1128/jcm.13.2.309-312.1981

Source DB:  PubMed          Journal:  J Clin Microbiol        ISSN: 0095-1137            Impact factor:   5.948


  6 in total

1.  A new approach to prophylactic therapy against the developing stages of Dirofilaria immitis before reaching the canine heart.

Authors:  S KUME; I OHISHI; S KOBAYASHI
Journal:  Am J Vet Res       Date:  1962-01       Impact factor: 1.156

2.  Titration of human serum antibodies to Toxoplasma gondii with a simple fluorometric assay.

Authors:  K W Walls; E R Barnhart
Journal:  J Clin Microbiol       Date:  1978-02       Impact factor: 5.948

3.  Dirofilaria immitis: cell-mediated and humoral immune responses in experimentally-infected dogs.

Authors:  R B Grieve; B M Gebhardt; R E Bradley
Journal:  Int J Parasitol       Date:  1979-08       Impact factor: 3.981

4.  Serology of amebiasis using the FIAX-TM system.

Authors:  R G Taylor; T R Pérez
Journal:  Arch Invest Med (Mex)       Date:  1978

5.  Indirect fluorescent antibody test in occult dirofilariasis.

Authors:  M M Wong; P F Suter
Journal:  Am J Vet Res       Date:  1979-03       Impact factor: 1.156

6.  Enzyme-linked immunosorbent assay for measurement of antibody responses to Dirofilaria immitis in experimentally infected dogs.

Authors:  R B Grieve; M Mika-Johnson; R H Jacobson; R H Cypess
Journal:  Am J Vet Res       Date:  1981-01       Impact factor: 1.156

  6 in total
  2 in total

1.  Pulmonary dirofilariasis in humans--pneumonitis that evolved to a lung nodule.

Authors:  L S Smith; R F Schillaci
Journal:  West J Med       Date:  1986-10

2.  A quantitative fluorometric assay for the measurement of antibody to Pasteurella haemolytica in cattle.

Authors:  A W Confer; J C Fox; P R Newman; G W Lawson; R E Corstvet
Journal:  Can J Comp Med       Date:  1983-01
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.