Literature DB >> 6991160

Total serum cholesterol by isotope dilution/mass spectrometry: a candidate definitive method.

A Cohen, H S Hertz, J Mandel, R C Paule, R Schaffer, L T Sniegoski, T Sun, M J Welch, E White.   

Abstract

We describe a highly accurate and precise method for determination of total cholesterol in serum by isotope dilution/mass spectrometry. The method was developed for a Study Group of the Committee on Standards of the American Association for Clinical Chemistry, for use in establishing the accuracy of a candidate reference method for total cholesterol, and fulfills their criteria for a definitive method. Cholesterol-d7 is added to serum, with the weight ratio of cholesterol-d7 to total serum cholesterol kept near to 1:1. The esters are hydrolyzed and the cholesterol is separated and converted into the trimethylsilyl ether derivative for measurement by combined gas chromatography/mass spectrometry. The intensity ratio of the molecular ions at m/z 465 and 458 is measured for each sample and for two calibration mixtures, according to a prescribed bracketing protocol. A weight ratio for the sample is obtained by linear interpolation of the ion-intensity ratios, and the total cholesterol is then calculated. The method was applied four times over several weeks to each of five serum pools. Statistical analysis involving consideration of both replication error and variability between weeks gave a coefficient of variation for a single measurement of 0.36%. The absence of interferences in the method was demonstrated by measurements at several other masses.

Entities:  

Mesh:

Substances:

Year:  1980        PMID: 6991160

Source DB:  PubMed          Journal:  Clin Chem        ISSN: 0009-9147            Impact factor:   8.327


  6 in total

Review 1.  Evolution of reference materials for the determination of organic nutrients in food and dietary supplements-a critical review.

Authors:  Stephen A Wise; Melissa M Phillips
Journal:  Anal Bioanal Chem       Date:  2018-12-01       Impact factor: 4.142

2.  Clinical chemistry through Clinical Chemistry: a journal timeline.

Authors:  Robert Rej
Journal:  Clin Chem       Date:  2004-12       Impact factor: 8.327

3.  Automated detection of inaccurate and imprecise transitions in peptide quantification by multiple reaction monitoring mass spectrometry.

Authors:  Susan E Abbatiello; D R Mani; Hasmik Keshishian; Steven A Carr
Journal:  Clin Chem       Date:  2009-12-18       Impact factor: 8.327

4.  Identification of a new plasma biomarker of Alzheimer's disease using metabolomics technology.

Authors:  Yoshiaki Sato; Ikumi Suzuki; Tatsuji Nakamura; Francois Bernier; Ken Aoshima; Yoshiya Oda
Journal:  J Lipid Res       Date:  2011-12-27       Impact factor: 5.922

5.  Certification of fat-soluble vitamins, carotenoids, and cholesterol in human serum: Standard Reference Material 968b.

Authors:  J B Thomas; M C Kline; S B Schiller; P M Ellerbe; L T Sniegoski; D L Duewer; K E Sharpless
Journal:  Anal Bioanal Chem       Date:  1996-08       Impact factor: 4.142

Review 6.  Analytical methods for cholesterol quantification.

Authors:  Li-Hua Li; Ewelina P Dutkiewicz; Ying-Chen Huang; Hsin-Bai Zhou; Cheng-Chih Hsu
Journal:  J Food Drug Anal       Date:  2018-10-04       Impact factor: 6.157

  6 in total