Literature DB >> 698139

The paper punched disc technique for lead in blood samples with abnormal haemoglobin values.

G F Carter.   

Abstract

A series of 15 blood samples with haemoglobin levels ranging from 4-6--16-1 g/dl were spotted on to Whatman No. 4 filter paper. Blood samples with low haemoglobin concentrations spread over a greater area of the filter paper than did those with high haemoglobin concentrations. This was further investigated by studying the performance of laboratory-prepared samples, and any effect on the estimation of blood lead value. Blood lead values assayed by the punched disc method on blood samples with low haemoglobin values were unreliable unless the estimated value was adjusted with respect to the area over which the blood had spread.

Mesh:

Substances:

Year:  1978        PMID: 698139      PMCID: PMC1008412          DOI: 10.1136/oem.35.3.235

Source DB:  PubMed          Journal:  Br J Ind Med        ISSN: 0007-1072


  4 in total

1.  Determination of blood lead using a 4-0 mm paper punched disc carbon sampling cup technique.

Authors:  A A Cernik
Journal:  Br J Ind Med       Date:  1974-07

2.  Accuracy and precision of two methods of blood lead estimation.

Authors:  A J Fox; M H Sayers
Journal:  Br J Ind Med       Date:  1973-10

3.  Determination of lead in capillary blood using a paper punched disc atomic absorption technique. Application to the supervision of lead workers.

Authors:  A A Cernik; M H Sayers
Journal:  Br J Ind Med       Date:  1971-10

4.  A micro-sampling method for the rapid determination of lead in blood by atomic-absorption spectrophotometry.

Authors:  H T Delves
Journal:  Analyst       Date:  1970-05       Impact factor: 4.616

  4 in total
  2 in total

1.  Characterization of the elemental composition of newborn blood spots using sector-field inductively coupled plasma-mass spectrometry.

Authors:  Erica K Langer; Kimberly J Johnson; Martin M Shafer; Patrick Gorski; Joel Overdier; Jessica Musselman; Julie A Ross
Journal:  J Expo Sci Environ Epidemiol       Date:  2010-06-30       Impact factor: 5.563

Review 2.  A state-of-the-science review and guide for measuring environmental exposure biomarkers in dried blood spots.

Authors:  Tyler A Jacobson; Jasdeep S Kler; Yeunook Bae; Jiexi Chen; Daniel T Ladror; Ramsunder Iyer; Denise A Nunes; Nathan D Montgomery; Joachim D Pleil; William E Funk
Journal:  J Expo Sci Environ Epidemiol       Date:  2022-08-13       Impact factor: 6.371

  2 in total