Literature DB >> 6978478

Evaluation of a commercial latex particle agglutination test for rapid diagnosis of Haemophilus influenzae type b infection.

R S Daum, G R Siber, J S Kamon, R R Russell.   

Abstract

The effectiveness of a commercially available latex particle agglutination test (Bactogen) in the diagnosis of invasive Haemophilus influenzae type b infection was evaluated. Bactogen correctly diagnosed all 27 patients with bacteriologically proven H influenzae type b infection (sensitivity 100%). Two of 39 patients with proven, non-H influenzae type b infections had false-positive tests (specificity 95%). One of 103 sera and 0 of 55 urine specimens from hospitalized adults contained detectable H influenzae type b antigen. Bactogen is a sensitive, specific, commercially available test for rapid diagnosis of H influenzae type b infection.

Entities:  

Mesh:

Substances:

Year:  1982        PMID: 6978478

Source DB:  PubMed          Journal:  Pediatrics        ISSN: 0031-4005            Impact factor:   7.124


  8 in total

1.  Rapid diagnosis of Haemophilus influenzae meningitis by a latex agglutination technique.

Authors:  M C Steinhoff; S John; G Koshi; M Jadhav; S M Pereira
Journal:  Indian J Pediatr       Date:  1984 Jul-Aug       Impact factor: 1.967

2.  Rapid diagnosis of severe Haemophilus influenzae serotype b infections by monoclonal antibody enzyme immunoassay for outer membrane proteins.

Authors:  A Belmaaza; J Hamel; S Mousseau; S Montplaisir; B R Brodeur
Journal:  J Clin Microbiol       Date:  1986-09       Impact factor: 5.948

3.  Improved detection of bacterial antigens by latex agglutination after rapid extraction from body fluids.

Authors:  L P Smith; K W Hunter; V G Hemming; G W Fischer
Journal:  J Clin Microbiol       Date:  1984-11       Impact factor: 5.948

4.  Preparation of urine samples for use in commercial latex agglutination tests for bacterial antigens.

Authors:  G A Weinberg; G A Storch
Journal:  J Clin Microbiol       Date:  1985-06       Impact factor: 5.948

5.  Detection of Haemophilus influenzae type b antigenuria by Bactigen and Phadebact kits.

Authors:  L Riera
Journal:  J Clin Microbiol       Date:  1985-04       Impact factor: 5.948

6.  Commercial latex agglutination tests for detection of Haemophilus influenzae type b and Streptococcus pneumoniae antigens in patients with bacteremic pneumonia.

Authors:  G W Ajello; G A Bolan; P S Hayes; D Lehmann; J Montgomery; J C Feeley; C A Perlino; C V Broome
Journal:  J Clin Microbiol       Date:  1987-08       Impact factor: 5.948

7.  Rapid bacterial antigen detection is not clinically useful.

Authors:  M D Perkins; S Mirrett; L B Reller
Journal:  J Clin Microbiol       Date:  1995-06       Impact factor: 5.948

8.  Comparison of a new, rapid enzyme-linked immunosorbent assay with latex particle agglutination for the detection of Haemophilus influenzae type b infections.

Authors:  A B Macone; G Arakere; J M Letourneau; D A Goldmann
Journal:  J Clin Microbiol       Date:  1985-05       Impact factor: 5.948

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.