Literature DB >> 6976359

Quantitative measurement of regional extravascular lung density using positron emission and transmission tomography.

C G Rhodes, P Wollmer, F Fazio, T Jones.   

Abstract

A technique has been developed to measure regional values of vascular and extravascular lung density using positron emission and transmission tomography. Quantitative values of lung density in a transaxial plane are obtained by recording transmission scans during the exposure of a ring source of positron emitting germanium/gallium-68, which encircles the subject in the plane of the scan. Values of blood density are obtained by scanning in the emission mode following the labeling of the subject's red blood cells with a quantity of C-carbon monoxide inhaled as a bolus. Subtraction of the normalised blood volume scan from the normalised lung density (transmission) scan provides regional values of extravascular lung density. The response of the transmission scan to changes in density was obtained by scanning different tissue equivalent materials in the density range 0.02 to 1.0 g cm-3. This resulted in a linear relationship between pixel counts and density. Density measurements made in vitro on simulated chest phantoms suggest that, at worst, random errors of 3.5% and systematic errors (due to the influence of the chest wall) of between 10 and 15% will be incurred when measurements are made in vivo on lungs of average normal density (0.3 g cm-3). The random error associated with the emission scan (arising from counting statistics alone) was found to be 1.2%. Measurements of lung density made on five normal subjects (supine) resulted in a mean density of 0.29 g cm-3 for a region in the lower (caudal) part of the lung, with a range of values between 0.26 and 0.32 g cm-3 from subject to subject. A pronounced anteroposterior gradient of both lung density and blood density was observed, while the gradient of extravascular lung density was quite small. The mean value of the ratio extravascular: vascular lung density for both caudal and cranial lung regions was 0.92 +/- 0.25.

Entities:  

Mesh:

Year:  1981        PMID: 6976359     DOI: 10.1097/00004728-198112000-00001

Source DB:  PubMed          Journal:  J Comput Assist Tomogr        ISSN: 0363-8715            Impact factor:   1.826


  28 in total

Review 1.  The perfusable tissue index: a marker of myocardial viability.

Authors:  Paul Knaapen; Ronald Boellaard; Marco J W Götte; Arno P van der Weerdt; Cees A Visser; Adriaan A Lammertsma; Frans C Visser
Journal:  J Nucl Cardiol       Date:  2003 Nov-Dec       Impact factor: 5.952

2.  Regional 2-[18F]fluoro-2-deoxy-D-glucose uptake varies in normal lung.

Authors:  T Miyauchi; R L Wahl
Journal:  Eur J Nucl Med       Date:  1996-05

3.  Quantitative SPECT by attenuation correction of the projection set using transmission data: evaluation of a method.

Authors:  H Almquist; J Palmer; M Ljungberg; P Wollmer; S E Strand; B Jonson
Journal:  Eur J Nucl Med       Date:  1990

4.  Correction of partial volume effects in myocardial SPECT.

Authors:  B F Hutton; A Osiecki
Journal:  J Nucl Cardiol       Date:  1998 Jul-Aug       Impact factor: 5.952

5.  The importance of correction for tissue fraction effects in lung PET: preliminary findings.

Authors:  Tryphon Lambrou; Ashley M Groves; Kjell Erlandsson; Nick Screaton; Raymondo Endozo; Thida Win; Joanna C Porter; Brian F Hutton
Journal:  Eur J Nucl Med Mol Imaging       Date:  2011-08-27       Impact factor: 9.236

6.  Effect of long-term beta2-agonist dosing on human cardiac beta-adrenoceptor expression in vivo: comparison with changes in lung and mononuclear leukocyte beta-receptors.

Authors:  F Qing; S U Rahman; M J Hayes; C G Rhodes; P W Ind; T Jones; J M Hughes
Journal:  J Nucl Cardiol       Date:  1997 Nov-Dec       Impact factor: 5.952

7.  Modeling of Tracer Transport Delays for Improved Quantification of Regional Pulmonary ¹⁸F-FDG Kinetics, Vascular Transit Times, and Perfusion.

Authors:  Tyler J Wellman; Tilo Winkler; Marcos F Vidal Melo
Journal:  Ann Biomed Eng       Date:  2015-05-05       Impact factor: 3.934

8.  Reduced beta adrenoceptor density in vivo in human lung tumours: a preliminary study with positron emission tomography.

Authors:  F Qing; M J Hayes; C G Rhodes; T Krausz; S W Fountain; M M Burke; T Jones; J M Hughes
Journal:  Thorax       Date:  1996-07       Impact factor: 9.139

9.  Estimation of regional gas and tissue volumes of the lung in supine man using computed tomography.

Authors:  D M Denison; M D Morgan; A B Millar
Journal:  Thorax       Date:  1986-08       Impact factor: 9.139

10.  Human dosimetry of carbon-11 labeled N-butan-2-yl-1-(2-chlorophenyl)-N-methylisoquinoline-3-carboxamide extrapolated from whole-body distribution kinetics and radiometabolism in rats.

Authors:  Pauliina Luoto; Iina Laitinen; Sami Suilamo; Kjell Någren; Anne Roivainen
Journal:  Mol Imaging Biol       Date:  2009-11-26       Impact factor: 3.488

View more