Literature DB >> 6968756

External quantification of myocardial perfusion by exponential infusion of positron-emitting radionuclides.

S N Hack, J O Eichling, S R Bergmann, M J Welch, B E Sobel.   

Abstract

A technique was developed and evaluated using the exponential infusion of positron-emitting diffusible tracers to quantitate myocardial perfusion. The approach employs a parameter that rapidly reaches a constant value as a function of tracer delivery rate, isotope decay constant, and the monotonically increasing tissue radioactivity. Isolated rabbit hearts with controlled flow were used to evaluate the approach, because tracer kinetics in such preparations mimic those in vivo. Accordingly, exponential infusions of H2 15O and [11C]butanol were administered to 25 isolated rabbit hearts perfused with Krebs-Henseleit solution (KH) alone or KH enriched with erythrocytes (KH-RBC, hematocrit = 40). With flow varied from 1.2 to 5 ml/g per min in eight KH hearts infused with H2 15O, actual and estimated flow correlated closely (r = 0.95, n = 52 determinations). For the KH-RBC hearts, flow was varied from 0.3 to 1.5 ml/g per min. Actual and estimated flow correlated significantly for both the 14 KH-RBC hearts infused with H2 15O (r = 0.90, n = 89 determinations) and the 3 KH-RBC hearts infused with [11C]butanol (r = 0.93, n = 13 determinations). In addition, the required exponentially increasing arterial tracer concentrations were shown to be attainable in vivo in dogs and rhesus monkeys after intravenous exponential administrations of tracer. The results suggest that the approach developed employing exponential tracer infusion permits accurate measurement of myocardial perfusion and that it should prove useful in the noninvasive measurement of regional myocardial perfusion in vivo by positron emission tomography.

Entities:  

Mesh:

Substances:

Year:  1980        PMID: 6968756      PMCID: PMC371526          DOI: 10.1172/JCI109959

Source DB:  PubMed          Journal:  J Clin Invest        ISSN: 0021-9738            Impact factor:   14.808


  17 in total

1.  The extraction of thallium-201 by the myocardium.

Authors:  H F Weich; H W Strauss; B Pitt
Journal:  Circulation       Date:  1977-08       Impact factor: 29.690

2.  Detection of remote myocardial infarction in patients with positron emission transaxial tomography and intravenous 11C-palmitate.

Authors:  B E Sobel; E S Weiss; M J Welch; B A Siegel; M M Ter-Pogossian
Journal:  Circulation       Date:  1977-06       Impact factor: 29.690

3.  Possibilities, limitations, and technique for the study of regional myocardial perfusion in man by Xenon-133.

Authors:  A Maseri; A L'abbate; C Michelassi; A Pesola; P Pisani; M Marzilli; M De Nes; P Mancini
Journal:  Cardiovasc Res       Date:  1977-07       Impact factor: 10.787

4.  Delayed coronary blood flow detected by computer analysis of serial scans.

Authors:  R O Smith; W D Love; P H Lehan; H K Hellems
Journal:  Am Heart J       Date:  1972-11       Impact factor: 4.749

5.  Estimation of coronary blood flow by washout of diffusible indicators.

Authors:  J B Bassingthwaighte; T Strandell; D E Donald
Journal:  Circ Res       Date:  1968-08       Impact factor: 17.367

6.  Clinical feasibility of myocardial imaging with 13 NH 3 .

Authors:  P V Harper; K A Lathrop; H Krizek; N Lembares; V Stark; P B Hoffer
Journal:  J Nucl Med       Date:  1972-04       Impact factor: 10.057

7.  Blood-brain barrier permeability of 11C-labeled alcohols and 15O-labeled water.

Authors:  M E Raichle; J O Eichling; M G Straatmann; M J Welch; K B Larson; M M Ter-Pogossian
Journal:  Am J Physiol       Date:  1976-02

8.  External quantification of myocardial ischemia and infarction with positron-emitting radionuclides.

Authors:  B E Sobel
Journal:  Adv Cardiol       Date:  1978

9.  Measurement of regional myocardial blood flow in man: description and critique of the method using xenon-133 and a scintillation camera.

Authors:  P J Cannon; R R Sciacca; D L Fowler; M B Weiss; D H Schmidt; W J Casarella
Journal:  Am J Cardiol       Date:  1975-11       Impact factor: 2.778

10.  Measurement of rCBE and rCMRO2 by continuous inhalation of 15O-labeled CO2 and O2.

Authors:  N M Alpert; R H Ackerman; J A Correia; J C Baron; G L Brownell; J M Taveras
Journal:  Acta Neurol Scand Suppl       Date:  1977
View more
  1 in total

1.  11C-butanol for imaging of the blood-flow distribution in tumor-bearing animals.

Authors:  W H Knapp; F Helus; F Oberdorfer; K Layer; H Sinn; H Ostertag; S Matzku
Journal:  Eur J Nucl Med       Date:  1985
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.