Literature DB >> 6958166

A novel miniature bite force recorder and its clinical application.

F Fløystrand, E Kleven, G Oilo.   

Abstract

Solid state components were used to construct a miniature bite force recorder suitable for registrations in large study groups. A semiconductor was chosen as the sensory unit. The complete recording system included a power supply, the bite force recorder, a chart recorder and a millivoltmeter. Laboratory calibration tests were performed to screen the limitations of the recorder. Series of loads were applied in the range from 10 to 1000 N. Eight females and eight males, 20 to 25 years old, were asked to produce a succession of maximum bites at three second intervals for as long as possible. The bite force recorder was positioned between the first molars on the left side. The laboratory tests showed that loads in the range from 10 to 1000 N were recorded with an error less than four percent. In the clinical tests, the mean maximal bite force was 500 N ranging from 330 to 680 N. The number of maximum bites varied from 5 to 27. No statistically significant differences were observed between the sexes as regards the maximal bite force and the number of bites.

Mesh:

Year:  1982        PMID: 6958166     DOI: 10.3109/00016358209019814

Source DB:  PubMed          Journal:  Acta Odontol Scand        ISSN: 0001-6357            Impact factor:   2.331


  5 in total

1.  A three-dimensional finite element analysis of the relationship between masticatory performance and skeletal malocclusion.

Authors:  Jung-Chul Park; Hyun-Seung Shin; Jung-Yul Cha; Jong-Tae Park
Journal:  J Periodontal Implant Sci       Date:  2015-02-25       Impact factor: 2.614

2.  Efficacy of denture adhesives in maxillary dentures using gnathodynamometry: a comparative study.

Authors:  Gregory Polyzois; Panagiotis Lagouvardos; Maria Frangou; Theodoros Stefaniotis
Journal:  Odontology       Date:  2011-04-12       Impact factor: 2.634

3.  Bite Force, Occlusal Contact and Pain in Orthodontic Patients during Fixed-Appliance Treatment.

Authors:  Nicoline Mie Therkildsen; Liselotte Sonnesen
Journal:  Dent J (Basel)       Date:  2022-01-19

4.  Bite force and influential factors on bite force measurements: a literature review.

Authors:  Duygu Koc; Arife Dogan; Bulent Bek
Journal:  Eur J Dent       Date:  2010-04

5.  Temporomandibular disorders, bite force and osseous changes of the temporomandibular joints in patients with hypermobile Ehlers-Danlos syndrome compared to a healthy control group.

Authors:  Karen Bech; Frederikke Maria Fogh; Eva Fejerskov Lauridsen; Liselotte Sonnesen
Journal:  J Oral Rehabil       Date:  2022-06-30       Impact factor: 3.558

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.