A three-dimensional finite element analysis of a porous rooted Co-Cr-Mo alloy dental implant.

S D Cook, A M Weinstein, J J Klawitter.   

Abstract

A three-dimensional finite element model was used to investigate the biomechanical response of a porous rooted Co-Cr-Mo alloy implant. The load displacement responses calculated from the finite element model were verified with experimentally-determined values for three-cylindrical, porous rooted Co-Cr-Mo alloy dental implants retrieved from canines after two years in function. Models were developed based on histological analyses of tissue surrounding the implants. The results of the study indicate that the assumption of a direct bone-to-implant interface (i.e., an ankylosed implant) may not be a good representation for a porous rooted implant retained by bone ingrowth.

Entities:  

Mesh:

Substances:

Year:  1982        PMID: 6948012     DOI: 10.1177/00220345820610010501

Source DB:  PubMed          Journal:  J Dent Res        ISSN: 0022-0345            Impact factor:   6.116


  12 in total

1.  The mechanical function of the periodontal ligament in the macaque mandible: a validation and sensitivity study using finite element analysis.

Authors:  Olga Panagiotopoulou; Kornelius Kupczik; Samuel N Cobb
Journal:  J Anat       Date:  2011-01       Impact factor: 2.610

2.  Study of Biomechanics of Porous Coated Root Form Implant Using Overdenture Attachment: A 3D FEA.

Authors:  Ravindra C Savadi; Chhavi Goyal
Journal:  J Indian Prosthodont Soc       Date:  2011-02-01

3.  [A FEM study for the biomechanical comparison of labial and palatal force application on the upper incisors. Finite element method].

Authors:  P G Jost-Brinkmann; K Tanne; M Sakuda; R R Miethke
Journal:  Fortschr Kieferorthop       Date:  1993-04

4.  Biomechanical consequences of rapid evolution in the polar bear lineage.

Authors:  Graham J Slater; Borja Figueirido; Leeann Louis; Paul Yang; Blaire Van Valkenburgh
Journal:  PLoS One       Date:  2010-11-05       Impact factor: 3.240

5.  The influence of the bone-implant interface stiffness on stress profiles surrounding Al2O3 and carbon dental implants.

Authors:  C J Lavernia; S D Cook; A M Weinstein; J J Klawitter
Journal:  Ann Biomed Eng       Date:  1982       Impact factor: 3.934

6.  Experimentally determined mechanical properties of, and models for, the periodontal ligament: critical review of current literature.

Authors:  Ted S Fill; Jason P Carey; Roger W Toogood; Paul W Major
Journal:  J Dent Biomech       Date:  2011-04-05

7.  Virtual reconstruction and prey size preference in the mid Cenozoic thylacinid, Nimbacinus dicksoni (Thylacinidae, Marsupialia).

Authors:  Marie R G Attard; William C H Parr; Laura A B Wilson; Michael Archer; Suzanne J Hand; Tracey L Rogers; Stephen Wroe
Journal:  PLoS One       Date:  2014-04-09       Impact factor: 3.240

8.  Force transfer and stress distribution in an implant-supported overdenture retained with a hader bar attachment: a finite element analysis.

Authors:  Preeti Satheesh Kumar; Kumar K S Satheesh; Jins John; Geetha Patil; Ruchi Patel
Journal:  ISRN Dent       Date:  2013-12-26

9.  Stress distribution patterns of implant supported overdentures-analog versus finite element analysis: A comparative in-vitro study.

Authors:  Soumyadev Satpathy; C L Satish Babu; Shilpa Shetty; Bharat Raj
Journal:  J Indian Prosthodont Soc       Date:  2015 Jul-Sep

10.  Computational biomechanical modelling of the rabbit cranium during mastication.

Authors:  Peter J Watson; Alana C Sharp; Tarun Choudhary; Michael J Fagan; Hugo Dutel; Susan E Evans; Flora Gröning
Journal:  Sci Rep       Date:  2021-06-23       Impact factor: 4.379

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.