Aortoduodenal fistula after surgery for renal artery stenosis.

R J Takolander, B F Ericsson, A Andersson, S E Bergentz.   

Abstract

An unusual case of aortoenteric fistulation, 5 years after surgery for renal artery stenosis, is presented. A stenotic right renal artery had been reimplanted into the aorta in a 4 1/2 year old boy. No signs of infection had been present, nor had any synthetic material been used. The fistula was found to originate from the ligated renal artery, not from the reconstruction. It was successfully corrected without compromising the kidney.

Entities:  

Mesh:

Year:  1980        PMID: 6941588

Source DB:  PubMed          Journal:  Acta Chir Scand Suppl        ISSN: 0301-1860


  1 in total

Review 1.  Enteric fistulation after renal artery reconstruction: a systematic literature review.

Authors:  David Bergqvist; Martin Björck
Journal:  World J Surg       Date:  2010-10       Impact factor: 3.352