Literature DB >> 6938134

Unilateral face-bows: a theoretical and laboratory analysis.

H G Hershey, C W Houghton, C J Burstone.   

Abstract

The investigation evaluated and compared the effectiveness of five face-bow types in delivering unilateral distal forces to their inner-bow terminals. The face-bow types evaluated were bilaterally symmetrical, soldered offset, spring attachment, swivel offset, and power arm. A strain-gauge transducer system was used in the laboratory analysis. A theoretical analysis was also conducted, patterned after the method of Haack and Weinstein, and the results were compared to those obtained from the laboratory analysis. The method used for the theoretical evaluation of the sample face-bows was found to be a reliable means of approximating the percentage distribution of distal forces to the inner-bow terminals. The magnitude and direction of the net lateral forces delivered to the inner-bow terminals was also reliably determined. The results of the theoretical and experimental study of the five face-bow types indicate that the power-arm unilateral face-bow and the swivel-offset unilateral face-bow were effective in delivering a clinically significant unilateral distal force. The bilaterally symmetrical face-bow, the soldered-offset unilateral face-bow, and the spring-attachment unilateral face-bow were not effective in delivering clinically significant unilateral distal forces. Every face-bow effective in delivering unilateral distal forces will also deliver a net lateral force to the inner-bow terminals. This net lateral force will have a direction running from the inner-bow terminal receiving the greater distal force toward the terminal receiving the lesser distal force.

Mesh:

Year:  1981        PMID: 6938134     DOI: 10.1016/0002-9416(81)90072-5

Source DB:  PubMed          Journal:  Am J Orthod        ISSN: 0002-9416


  9 in total

1.  [How effective is asymmetrical headgear in practical use?].

Authors:  A Wichelhaus; F G Sander; E Inglezos
Journal:  Fortschr Kieferorthop       Date:  1995-11

2.  [Orthodontic measuring and simulating systems (OMSS) for the static and dynamic analysis of tooth movement].

Authors:  D Drescher; C Bourauel; M Thier
Journal:  Fortschr Kieferorthop       Date:  1991-06

3.  [The effect of molar position on the distalization behavior of indirect headgear].

Authors:  M Breier; C Bourauel; D Drescher; C W Schwarze
Journal:  Fortschr Kieferorthop       Date:  1995-07

4.  Comparison of two asymmetric headgear force systems: A finite element analysis.

Authors:  Samaneh Sadeghi; Zohreh Hedayati; Batoolalsadat Mousavi-Fard
Journal:  Dental Press J Orthod       Date:  2019-05-20

5.  [The lateral and transverse forces with indirect headgear and its modifications].

Authors:  M Breier; D Drescher; C Bourauel
Journal:  Fortschr Kieferorthop       Date:  1993-04

6.  [Headgear-free molar distalization].

Authors:  C Manhartsberger
Journal:  Fortschr Kieferorthop       Date:  1994-12

7.  Biomechanical reevaluation of orthodontic asymmetric headgear.

Authors:  Lu Chi; Mulin Cheng; H Garland Hershey; Tung Nguyen; Ching-Chang Ko
Journal:  Angle Orthod       Date:  2011-12-08       Impact factor: 2.079

8.  Unilateral Outer Bow Expanded Cervical Headgear Force System: 3D Analysis Using Finite Element Method.

Authors:  Allahyar Geramy; Omid Mortezai; Masomeh Esmaily; Hojat Darvishpour
Journal:  J Dent (Tehran)       Date:  2015-04

9.  Asymmetric Outer Bow Length and Cervical Headgear Force System: 3D Analysis Using Finite Element Method.

Authors:  Allahyar Geramy; Mehdi Hassanpour; Elham Sadat Emadian Razavi
Journal:  J Dent (Tehran)       Date:  2015-03
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.