Literature DB >> 6929810

Linear dimensional changes in elastic impression materials.

C F Marcinak, F A Young, R A Draughn, W R Flemming.   

Abstract

Four classes of elastomeric impression materials (polysulfide, polyether, silicone, and agar-agar) were evaluated on the basis of linear dimensional stability as a function of time between taking and pouring an impression of mounted teeth. Four polysulfide materials produced dies which were larger than the teeth and generally increased in size with impression storage time. One silicone material produced dies slightly smaller than the teeth, and the dies from another silicone were dramatically smaller with increasing storage times. A polyether material produced slightly smaller dies for up to four hours' storage time, then increasingly larger dies up to 24 h. The dies from a reversible hydrocolloid were larger than the teeth for storage times up to 30 min, and then decreased rapidly at longer times.

Entities:  

Mesh:

Substances:

Year:  1980        PMID: 6929810     DOI: 10.1177/00220345800590071001

Source DB:  PubMed          Journal:  J Dent Res        ISSN: 0022-0345            Impact factor:   6.116


  5 in total

1.  Biocorrosion properties of antibacterial Ti-10Cu sintered alloy in several simulated biological solutions.

Authors:  Cong Liu; Erlin Zhang
Journal:  J Mater Sci Mater Med       Date:  2015-03-04       Impact factor: 3.896

2.  Comparison of disinfectants by immersion and spray atomization techniques on the linear dimensional stability of different interocclusal recording materials: An in vitro study.

Authors:  Revathy Gounder; B V J Vikas
Journal:  Eur J Dent       Date:  2016 Jan-Mar

3.  Comparative evaluation of dimensional stability of impression materials from developing countries and developed countries after disinfection with different immersion disinfectant systems and ultraviolet chamber.

Authors:  Rupandeep Kaur Samra; Shreenivas Vasant Bhide
Journal:  Saudi Dent J       Date:  2017-12-13

4.  Comparison of the surface roughness of gypsum models constructed using various impression materials and gypsum products.

Authors:  Yi-Chih Chang; Chien-Hung Yu; Wen-Miin Liang; Ming-Gene Tu; San-Yue Chen
Journal:  J Dent Sci       Date:  2013-02-04       Impact factor: 2.080

5.  Effect of storage period on the accuracy of elastomeric impressions.

Authors:  Eduardo Batista Franco; Leonardo Fernandes da Cunha; Ana Raquel Benetti
Journal:  J Appl Oral Sci       Date:  2007-06       Impact factor: 2.698

  5 in total