Literature DB >> 6909023

Programs SARGON and DELTA: two new principles for the automated analysis of the visual field.

F Fankhauser, A Jenni.   

Abstract

The new Octopus programs SARGON and DELTA are described. The SARGON program makes possible the arbitrary distribution of a maximum number of 66 test locations with a resolution of up to 0.2 degrees across the 60 degrees visual field. Eighty user-defined self-created programs can be permanently stored and recalled later at will from the program diskette.. The program DELTA evaluates perimetric examination results with the aid of a series of statistical tests and investigates whether the data base is sufficient to assume a significant deviation, or alternatively, whether a visual field defect can be explained simply by spontaneous fluctuations or if a true pathologic defect should be assumed at a particular level of significance. Furthermore, the program tests changes in the visual field as a function of time for their statistical significance.

Entities:  

Mesh:

Year:  1981        PMID: 6909023     DOI: 10.1007/bf00407775

Source DB:  PubMed          Journal:  Albrecht Von Graefes Arch Klin Exp Ophthalmol        ISSN: 0065-6100


  5 in total

1.  [Automation of perimetry. Demonstration methods of results of perimetric examinations].

Authors:  B Weber; J Spahr
Journal:  Acta Ophthalmol (Copenh)       Date:  1976-07

2.  Changes of glaucomatous field defects. Degree of accuracy of measurements with the automatic perimeter Octopus.

Authors:  B Gloor; U Schmied; A Faessler
Journal:  Int Ophthalmol       Date:  1980-12       Impact factor: 2.031

3.  [A statistical program for determining fields of vision (author's transl)].

Authors:  H Bebie; F Fankhauser
Journal:  Klin Monbl Augenheilkd       Date:  1980-10       Impact factor: 0.700

4.  Octopus programs SAPRO and F. Two new principles for the analysis of the visual field.

Authors:  F Fankhauser; H Häberlin; A Jenni
Journal:  Albrecht Von Graefes Arch Klin Exp Ophthalmol       Date:  1981

5.  [Glaucomatous visual fields: observation of development with the Octopus automatic perimeter (author's transl)].

Authors:  B Gloor; A Fässler; B Lüdin
Journal:  Klin Monbl Augenheilkd       Date:  1980-12       Impact factor: 0.700

  5 in total
  4 in total

1.  Octopus programs SAPRO and F. Two new principles for the analysis of the visual field.

Authors:  F Fankhauser; H Häberlin; A Jenni
Journal:  Albrecht Von Graefes Arch Klin Exp Ophthalmol       Date:  1981

2.  Programmed visual field testing.

Authors:  D R Anderson
Journal:  Trans Am Ophthalmol Soc       Date:  1982

Review 3.  Detection and measurement of clinically meaningful visual field progression in clinical trials for glaucoma.

Authors:  C Gustavo De Moraes; Jeffrey M Liebmann; Leonard A Levin
Journal:  Prog Retin Eye Res       Date:  2016-10-20       Impact factor: 21.198

4.  Performance of computer assisted perimeters.

Authors:  E L Greve
Journal:  Doc Ophthalmol       Date:  1982-12-01       Impact factor: 2.379

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.