Literature DB >> 6893672

Pitfalls in double contrast knee arthrography.

I Watt, T Tasker.   

Abstract

Two hundred and forty-two patients investigated by double-contrast knee arthrography between 1973 and 1977 have reviewed. Of these 134 have come to arthrotomy and an initial arthrographic accuracy of 85% is reported. An attempt to explain the disparities between arthrography and arthrotomy has revealed that in half the cases (ten patients) there were simple reporting errors on the arthrograms. These are shown all to be false negative reports. The other group of ten patients comprised presumed errors in arthrotomy interpretation in four and arthrographic interpretation or technical failure in six. The causes and implications of those errors are analysed and discussed.

Entities:  

Mesh:

Year:  1980        PMID: 6893672     DOI: 10.1259/0007-1285-53-632-754

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039