Literature DB >> 689020

A method for the measurement of tremor, and a comparison of the effects of tocolytic beta-mimetics.

K Behling, A Bleichert, M Scarperi.   

Abstract

A method permitting measurement of finger tremor as a displacement-time curve is described, using a test system with simple amplitude calibration. The coordinates of the inversion points of the displacement-time curves were transferred through graphical input equipment to punched tape. By means of a computer program, periods and amplitudes of tremor oscillations were calculated and classified. The event frequency for each class of periods and amplitudes was determined. The actions of fenoterol-hydrobromide, ritodrin-HCl and placebo given to 10 healthy subjects by intravenous infusion in a double-blind crossover study were tested by this method. At therapeutic doses both substances raised the mean tremor amplitude to about three times the control level. At the same time, the mean period within each class of amplitudes shortened by 10--20 ms, whereas the mean periods calculated from all oscillations together did not change significantly. After the end of fenoterol-hydrobromide infusion, tremor amplitudes decreased significantly faster than those following ritodrin-HCl infusion.

Entities:  

Mesh:

Substances:

Year:  1978        PMID: 689020     DOI: 10.1007/BF00421347

Source DB:  PubMed          Journal:  Eur J Appl Physiol Occup Physiol        ISSN: 0301-5548


  5 in total

1.  [Tremor recording with the infraton-pulse taker].

Authors:  J Finke; D Bachhausen
Journal:  Nervenarzt       Date:  1976-05       Impact factor: 1.214

2.  [Reflex time determination and tremor registration using the Infraton pulse registration set].

Authors:  D Klaus; J Finke; W Fahlbusch; D Bachhausen
Journal:  Med Welt       Date:  1974-04-19

3.  [A simple method for measurement of tremor (author's transl)].

Authors:  H Herz; L Nusselt
Journal:  Biomed Tech (Berl)       Date:  1973-12       Impact factor: 1.411

4.  Peripheral beta-adrenergic receptors concerned with tremor.

Authors:  C D Marsden; T H Foley; D A Owen; R G McAllister
Journal:  Clin Sci       Date:  1967-08       Impact factor: 6.124

5.  Validity of quantitative tests measuring tremor.

Authors:  A R Potvin; W W Tourtellotte; D N Snyder; W G Henderson; J W Albers
Journal:  Am J Phys Med       Date:  1975-10
  5 in total
  1 in total

1.  Occupational exposure to hexachlorocyclohexane. III neurophysiological findings and neuromuscular function in chronically exposed workers.

Authors:  K Baumann; K Behling; H L Brassow; K Stapel
Journal:  Int Arch Occup Environ Health       Date:  1981       Impact factor: 3.015

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.