Literature DB >> 6885254

Contact glass for use with high power lasers--geometrical and optical aspects. Solution for the angle of the anterior chamber.

P Roussel, F Fankhauser.   

Abstract

A new mirror contact glass for irradiation of pathological structures within the angle of the anterior chamber with high power lasers is described. The new contact glass is distinguished by its optimized optical characteristics. Due to its spherical front surface, tipping movements, as necessary in inspection and aiming manoeuvres, have no significant influence on the focus diameter. That the imaging quality is independent of the contact glass manipulations is seen as essential for laser surgical tasks with high power lasers, since changes in the focus diameter critically affect the power density at the focus and thus the intensity of the microsurgical effects. The increased spatial reliability of the laser-induced microexplosion is thought to be a further merit of the new contact glass.

Mesh:

Year:  1983        PMID: 6885254     DOI: 10.1007/bf00141127

Source DB:  PubMed          Journal:  Int Ophthalmol        ISSN: 0165-5701            Impact factor:   2.031


  6 in total

1.  Changes in the ultrastructure of the iris after irradiation with intense light. A study of long-term effects after irradiation with argon ion, Nd:YAG and Q-switched ruby lasers.

Authors:  E van der Zypen; F Fankhauser; H Bebie; J Marshall
Journal:  Adv Ophthalmol       Date:  1979

2.  Q-switched laser goniopuncture.

Authors:  M M Krasnov
Journal:  Arch Ophthalmol       Date:  1974-07

3.  Protocol for single-session argon laser iridectomy for angle-closure glaucoma.

Authors:  R K Abraham
Journal:  Int Ophthalmol Clin       Date:  1981

4.  [Argon laser iridectomy and gonioplasty in the treatment of angle-closure glaucoma].

Authors:  K E Schirmer
Journal:  Klin Monbl Augenheilkd       Date:  1982-08       Impact factor: 0.700

5.  Clinical studies on high and low power laser radiation upon some structures of the anterior and posterior segments of the eye. Experiences in the treatment of some pathological conditions of the anterior and posterior segments of the human eye by means of a Nd:YAG laser, driven at various power levels.

Authors:  F Fankhauser; H Lörtscher; E van der Zypen
Journal:  Int Ophthalmol       Date:  1982-05       Impact factor: 2.031

6.  [Ophthalmological use of pulsated Neodymium Yag lasers. Preoperative aperture of lenses previous setting in of artificial lenses and opening of secondary cataracts behind implants (author's transl)].

Authors:  D Aron-Rosa; J C Griesemann; J J Aron
Journal:  J Fr Ophtalmol       Date:  1981       Impact factor: 0.818

  6 in total
  3 in total

Review 1.  Lasers, optical systems and safety in ophthalmology: a review.

Authors:  F Fankhauser; U Dürr; H Giger; P Rol; S Kwasniewska
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  1996-08       Impact factor: 3.117

2.  Contact glasses for use with high power lasers. Two new contact glasses for microsurgery at the iris, in the pupillary and the retropupillary space.

Authors:  D Riquin; F Fankhauser; H Lörtscher
Journal:  Int Ophthalmol       Date:  1983-06       Impact factor: 2.031

3.  'Contact glass for use with high power lasers--geometrical and optical aspects', by P. Roussel and F. Fankhauser (1).

Authors:  W Lotmar
Journal:  Int Ophthalmol       Date:  1984-06       Impact factor: 2.031

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.