Literature DB >> 6883418

Turbulent blood flow in the ascending aorta of dogs.

H L Falsetti, R J Carroll, R D Swope, C J Chen.   

Abstract

A conical hot film anemometer probe was used to measure instantaneous velocities in the ascending aorta of anaesthetised, open-chest dogs. The probe was mounted on a saddle which allowed traversal of the aorta in 1 mm increments 4 cm above the aortic valve. From these point measurements, the radial distribution of velocity was obtained by averaging ten cardiac cycles. The contractile state of the heart was increased by sequential intravenous infusions of isoprenaline. The absolute peak centreline velocity in the baseline state ranged from 28 to 56 cm x s-1 and, in 20 micrograms x min-1 isoprenaline infusion, from 39 to 112 cm x s-1. Two major effects of isoprenaline on blood flow were noted: 1) isoprenaline dramatically increased peak centreline velocity, and 2) disturbances resembling turbulence appeared as peak velocity increased. With isoprenaline infusion disturbances existed throughout the deceleration portion of the aortic blood flow. Analysis of the frequency components of the velocity wave was performed, and significantly higher frequency components up to 100 Hertz were found in the turbulent cases compared to the laminar ones. Turbulent flow or disturbed flow is found when the ratio of Reynolds number to Womersley number is above 200. In general the hot film measurements showed that both laminar and disturbed velocity profiles tended to be flat throughout the cardiac cycle, with the sharp velocity gradient confined to the region of the wall. Turbulent normal stress during the deceleration portion of aortic blood flow were found in the orders of 15 to 30 dynes x cm-2 and the wall shear stresses were found to be from 10 dynes x cm-2 at the baseline condition to 50 dynes x cm-2 during the 20 micrograms x min-1 isoprenaline infusion.

Entities:  

Mesh:

Substances:

Year:  1983        PMID: 6883418     DOI: 10.1093/cvr/17.7.427

Source DB:  PubMed          Journal:  Cardiovasc Res        ISSN: 0008-6363            Impact factor:   10.787


  6 in total

Review 1.  Doppler echocardiography for the estimation of cardiac output with exercise.

Authors:  Thomas Rowland; Philippe Obert
Journal:  Sports Med       Date:  2002       Impact factor: 11.136

2.  Blood flow patterns in the human aorta studied by magnetic resonance.

Authors:  W A Seed
Journal:  Br Heart J       Date:  1988-08

3.  Changes in left ventricular stroke volume measured by Doppler echocardiography.

Authors:  H Ihlen; E Myhre; J Pamlie; K Forfang; S Larsen
Journal:  Br Heart J       Date:  1985-10

4.  Combined In Silico and In Vitro Approach Predicts Low Wall Shear Stress Regions in a Hemofilter that Correlate with Thrombus Formation In Vivo.

Authors:  Amanda K W Buck; Joseph J Groszek; Daniel C Colvin; Sara B Keller; Clark Kensinger; Rachel Forbes; Seth Karp; Phillip Williams; Shuvo Roy; William H Fissell
Journal:  ASAIO J       Date:  2018 Mar/Apr       Impact factor: 2.872

5.  Cardiac stroke volume during exercise measured by Doppler echocardiography: comparison with the thermodilution technique and evaluation of reproducibility.

Authors:  H Ihlen; K Endresen; S Golf; S Nitter-Hauge
Journal:  Br Heart J       Date:  1987-11

6.  Continuous wave Doppler cardiac output: use in pediatric patients receiving inotropic support.

Authors:  W R Morrow; D J Murphy; D J Fisher; J C Huhta; L S Jefferson; E O Smith
Journal:  Pediatr Cardiol       Date:  1988       Impact factor: 1.655

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.