Literature DB >> 6878678

Arthrography after total hip arthroplasty: a modified technique used in the diagnosis of pain.

R W Hendrix, R L Wixson, N A Rana, L F Rogers.   

Abstract

The results of plain film radiography and arthrography in diagnosing loosening of a prosthetic component after total hip arthroplasty were correlated with surgical findings in 31 patients who required surgery because of hip pain. The accuracy of arthrography in diagnosing component loosening using 5 ml of contrast material was 51%, and the accuracy of plain radiography was 69%. An accuracy of 92% was achieved using a modified arthrographic technique in which the pressure in the joint was recorded after injection of contrast material and while the patient walked to ensure that it was comparable with the pressure that caused the patient's pain prior to the study. Three per cent of the arthrographic studies using this technique were false negative and 5% were false positive.

Entities:  

Mesh:

Substances:

Year:  1983        PMID: 6878678     DOI: 10.1148/radiology.148.3.6878678

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  12 in total

1.  Early polyethylene wear and osteolysis with ABG acetabular cups (7- to 12-year follow-up).

Authors:  Sachin Badhe; Peter Livesley
Journal:  Int Orthop       Date:  2005-11-08       Impact factor: 3.075

2.  Arthrography of painful hips following arthroplasty: digital versus plain film subtraction.

Authors:  C W Walker; R L FitzRandolph; D N Collins; G V Dalrymple
Journal:  Skeletal Radiol       Date:  1991       Impact factor: 2.199

3.  Arthrography after total hip arthroplasty: utility of postambulation radiographs.

Authors:  D C Hardy; W R Reinus; W G Totty; C K Keyser
Journal:  Skeletal Radiol       Date:  1988       Impact factor: 2.199

4.  The value of contrast arthrography in assessing loosening of symptomatic uncemented total hip components.

Authors:  R L Barrack; M Tanzer; S V Kattapuram; W H Harris
Journal:  Skeletal Radiol       Date:  1994-01       Impact factor: 2.199

5.  Contrast and nuclear arthrography in loosening of the uncemented hip prosthesis.

Authors:  J S Swan; E M Braunstein; H N Wellman; W Capello
Journal:  Skeletal Radiol       Date:  1991       Impact factor: 2.199

6.  Fluid pressure and flow as a cause of bone resorption.

Authors:  Anna Fahlgren; Mathias P G Bostrom; Xu Yang; Lars Johansson; Ulf Edlund; Fredrik Agholme; Per Aspenberg
Journal:  Acta Orthop       Date:  2010-08       Impact factor: 3.717

7.  Clinical value of combined contrast and radionuclide arthrography in suspected loosening of hip prostheses.

Authors:  G Köster; D L Munz; H P Köhler
Journal:  Arch Orthop Trauma Surg       Date:  1993       Impact factor: 3.067

Review 8.  Osteolysis around total knee arthroplasty: a review of pathogenetic mechanisms.

Authors:  J Gallo; S B Goodman; Y T Konttinen; M A Wimmer; M Holinka
Journal:  Acta Biomater       Date:  2013-05-10       Impact factor: 8.947

9.  Nuclear factor of activated T cells mediates fluid shear stress- and tensile strain-induced Cox2 in human and murine bone cells.

Authors:  Ayse B Celil Aydemir; Hiroshi Minematsu; Thomas R Gardner; Kyung Ok Kim; Jae Mok Ahn; Francis Young-In Lee
Journal:  Bone       Date:  2009-09-11       Impact factor: 4.398

10.  In vitro influence of stem surface finish and mantle conformity on pressure generation in cemented hip arthroplasty.

Authors:  Gavin E Bartlett; Harinderjit S Gill; David W Murray; David J Beard
Journal:  Acta Orthop       Date:  2009-04       Impact factor: 3.717

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.