Valve-related complications after Björk-Shiley mitral valve implantation (n = 475), aortic valve implantation (n = 424), or mitral-aortic valve implantation (n = 119) were compared with those after St. Jude Medical mitral valve replacement (n = 173), aortic valve replacement (n = 152), or mitral-aortic valve replacement (n = 69). All patients were placed on anticoagulant therapy with phenprocoumon early after operation. All patients had a comparable follow-up time of approximately 23 months, which showed that cumulative thromboembolic rates were significantly higher after St. Jude valve implantation than after Björk-Shiley valve implantation. Reoperations were necessary because of valve thrombosis (0.46%), perivalvular leakage (2.2%), or prosthetic valve endocarditis with perivalvular regurgitation (0.46%). One Björk-Shiley mitral valve prosthesis had to be replaced because of fracture of the outlet strut. Without significant intergroup differences, hemorrhage due to anticoagulant treatment was the most frequent complication. Thromboembolic complications were significantly more frequent after Björk-Shiley mitral, aortic, and double valve replacements than after St. Jude valve implantation. This may lead to consideration of changes in the prophylaxis of thrombus formations in the St. Jude valve, especially in aortic valve replacements, in patients with sinus rhythm.

Entities:  

Mesh:

Year:  1983        PMID: 6872190

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  8 in total

1.  Hemolysis after mitral valve replacement with mechanical valve prostheses.

Authors:  M Ninomiya; K Yagyu; Y Kaneko; Y Kotsuka; S Takamoto
Journal:  Jpn J Thorac Cardiovasc Surg       Date:  2001-04

2.  Perivalvular leakage 25 years after initial mitral valve replacement with a Björk-Shiley prosthesis.

Authors:  Hiroya Minami; Tatsuro Asada; Kunio Gan
Journal:  Gen Thorac Cardiovasc Surg       Date:  2008-09-13

3.  Midterm results of aortic valve replacement with cryopreserved homografts.

Authors:  Can Vuran; Paul Simon; Gregor Wollenek; Emre Ozker; Erdal Aslım
Journal:  Balkan Med J       Date:  2012-06-01       Impact factor: 2.021

4.  Instantaneous back flow through peripheral clearance of Medtronic Hall tilting disc valve at the moment of closure.

Authors:  C S Lee; K B Chandran
Journal:  Ann Biomed Eng       Date:  1994 Jul-Aug       Impact factor: 3.934

Review 5.  Drug treatment associated with heart valve replacement.

Authors:  D S Coulshed; M A Fitzpatrick; C H Lee
Journal:  Drugs       Date:  1995-06       Impact factor: 9.546

6.  Obstruction of mechanical valve prostheses: clinical diagnosis and surgical or nonsurgical treatment.

Authors:  S Aoyagi; S Fukunaga; S Suzuki; Y Nishi; A Oryoji; K Kosuga
Journal:  Surg Today       Date:  1996       Impact factor: 2.549

7.  Transcatheter paravalvular leak closure and hemolysis - a prospective registry.

Authors:  Grzegorz Smolka; Piotr Pysz; Andrzej Ochała; Michał Kozłowski; Wojciech Zasada; Zofia Parma; Michał Tendera; Wojciech Wojakowski
Journal:  Arch Med Sci       Date:  2016-06-13       Impact factor: 3.318

8.  Multiple paravalvular leak 17 years after a second mitral valve replacement.

Authors:  Tae-Eun Jung; Dong-Hyup Lee
Journal:  J Cardiothorac Surg       Date:  2013-02-15       Impact factor: 1.637