Literature DB >> 6871425

Theoretical modeling of filtration of blood cell suspensions.

R Skalak, T Impelluso, E A Schmalzer, S Chien.   

Abstract

A theoretical model of filtration of suspensions containing red blood cells (RBCs) and white blood cells (WBCs) has been developed. Equations are written for the pressure drop, the filtration flow and the fractions of filter pores containing RBCs (alpha) and WBCs (alpha*). Because the relative resistances (ratios of resistance of cell to resistance of suspending fluid) of RBCs (beta) and WBCs (beta*) through the filter pore are greater than one, the transit of these cells (especially WBCs) through the filter is slower than that of suspending fluid; this leads to values of alpha and alpha* higher than those simply expected from the hematocrit and leukocrit, respectively, in the entering and exiting suspensions. In the absence of pore plugging by the cells (steady flow), the pressure drop can be computed from alpha, alpha*, beta and beta*. In order to model unsteady flow, differential equations are written to include pore plugging and the subsequent unplugging by the rising filtration pressure at a constant flow. By specifying the fractions of entering RBCs (epsilon) and WBCs (epsilon*) which would plug the pores and the rate at which the plugged pores would unplug in response to pressure rise (epsilon u), as well as the fractions of entering RBCs (epsilon p) and WBCs (epsilon p*) that would plug the pores permanently, theoretical pressure-time curves can be generated by numerical integration, and the results fit the experimental data well. From such fitting of theoretical curve to experimental data, information can be deduced for epsilon, epsilon*, epsilon u, epsilon p and epsilon* p.

Mesh:

Year:  1983        PMID: 6871425     DOI: 10.3233/bir-1983-20104

Source DB:  PubMed          Journal:  Biorheology        ISSN: 0006-355X            Impact factor:   1.875


  8 in total

1.  High-speed microfluidic differential manometer for cellular-scale hydrodynamics.

Authors:  Manouk Abkarian; Magalie Faivre; Howard A Stone
Journal:  Proc Natl Acad Sci U S A       Date:  2006-01-05       Impact factor: 11.205

Review 2.  New perspectives on basic mechanisms in lung disease. 2. Neutrophil traffic in the lungs: role of haemodynamics, cell adhesion, and deformability.

Authors:  W MacNee; C Selby
Journal:  Thorax       Date:  1993-01       Impact factor: 9.139

3.  Microhemodynamic aberrations created by transfusion of stored blood.

Authors:  Ozlem Yalcin; Daniel Ortiz; Amy G Tsai; Paul C Johnson; Pedro Cabrales
Journal:  Transfusion       Date:  2013-07-31       Impact factor: 3.157

4.  Mesenchymal Stem Cell Deformability and Implications for Microvascular Sequestration.

Authors:  Herbert H Lipowsky; Daniel T Bowers; Brittany L Banik; Justin L Brown
Journal:  Ann Biomed Eng       Date:  2018-01-19       Impact factor: 3.934

5.  A microfabricated deformability-based flow cytometer with application to malaria.

Authors:  Hansen Bow; Igor V Pivkin; Monica Diez-Silva; Stephen J Goldfless; Ming Dao; Jacquin C Niles; Subra Suresh; Jongyoon Han
Journal:  Lab Chip       Date:  2011-02-03       Impact factor: 6.799

6.  Blood Quality Diagnostic Device Detects Storage Differences Between Donors.

Authors:  Vivek P Jani; Shawn Mailo; Ali Athar; Alfredo Lucas; Alexander T Williams; Pedro Cabrales
Journal:  IEEE Trans Biomed Circuits Syst       Date:  2017-10-05       Impact factor: 3.833

7.  Rat red blood cell storage lesions in various additive solutions.

Authors:  Vivek P Jani; Ozlem Yalcin; Alexander T Williams; Mark A Popovsky; Pedro Cabrales
Journal:  Clin Hemorheol Microcirc       Date:  2017       Impact factor: 2.375

8.  Filtration parameters influencing circulating tumor cell enrichment from whole blood.

Authors:  Frank A W Coumans; Guus van Dalum; Markus Beck; Leon W M M Terstappen
Journal:  PLoS One       Date:  2013-04-26       Impact factor: 3.240

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.