Quantitative histologic evaluation of LTI carbon, carbon-coated aluminum oxide and uncoated aluminum oxide dental implants.

S D Cook, A M Weinstein, J J Klawitter, J N Kent.   

Abstract

The response of mandibular bone to identical geometry LTI carbon, carbon-coated aluminum oxide, and uncoated aluminum oxide blade-type dental implants in baboons for 2 years was evaluated using histologic, microradiographic, and scanning electron microscopic methods. In addition, a quantitative histologic analysis was performed identifying the type, amount, and distribution of tissue surrounding the dental implant systems. This is the final phase of a study investigating the effect of implant elastic modulus and implant surface chemical composition on the performance of dental implants. Previous studies have utilized clinical and radiographic evaluations, postretrieval mechanical testing, and finite element stress analysis to evaluate the dental implant performance. The results of the histologic study revealed a direct implant-bone interface with no intervening soft tissue in 16 of the 21 implants (76%). A fibrous tissue interface was observed in 5 of 21 implants (24%). Quantitative histologic results for the implants with a direct implant-bone interface showed statistically larger crestal cortical plates (p less than 0.05) and greater area fraction crestal cancellous bone (p less than 0.05) in the LTI carbon implant compared to the carbon-coated and uncoated aluminum oxide implants. The carbon-coated and uncoated aluminum oxide implants demonstrated statistically greater area fraction cancellous bone at the inferior region of the implant (p less than 0.05) and thinned and reduced crestal cortical plates when compared to the LTI carbon implants. The results indicate that significant stress shielding of the crestal bone had occurred with the rigid carbon-coated and uncoated aluminum oxide implants when compared to the LTI carbon implants which had a material elastic modulus similar to cortical bone. Based upon the histologic results, it appears that the LTI carbon implants with the direct implant-bone interface exhibited a greater potential for long-term successful performance compared to the aluminum oxide substrate implants.

Entities:  

Mesh:

Substances:

Year:  1983        PMID: 6863353     DOI: 10.1002/jbm.820170311

Source DB:  PubMed          Journal:  J Biomed Mater Res        ISSN: 0021-9304


  2 in total

1.  The improved biological performance of a novel low elastic modulus implant.

Authors:  Lei Shi; Lei Shi; Ling Wang; Yonghong Duan; Wei Lei; Zhen Wang; Jing Li; Xiangli Fan; Xiaokang Li; Shujun Li; Zheng Guo
Journal:  PLoS One       Date:  2013-02-21       Impact factor: 3.240

2.  Biological and functional evaluation of a novel pyrolytic carbon implant for the treatment of focal osteochondral defects in the medial femoral condyle: assessment in a canine model.

Authors:  Samantha L Salkeld; Laura P Patron; Joan C Lien; Stephen D Cook; Deryk G Jones
Journal:  J Orthop Surg Res       Date:  2016-12-01       Impact factor: 2.359