Literature DB >> 6861786

Physical requirements of a 59Fe bone marrow distribution digital scanning study.

B Aubert, E Kahn, C Parmentier, R Di Paola.   

Abstract

A method is described to provide whole-body scannings of 59Fe bone marrow distribution using a tungsten-alloy collimator. The physical requirements of this method were determined by means of dedicated phantoms. As we were only interested in bounded 59Fe regions (sacral bone, liver and spleen), it was necessary to subtract the 59Fe activity in the blood. An estimate of this activity was obtained by means of 99mTc-labelled erythrocyte whole-body scanning to which a correction factor K was applied. The independence versus depth was performed by computing geometrical means of prone and supine images. The results of these experiments indicate the possible feasibility of a scanning method for a ferrokinetic study in place of the usual external counting.

Mesh:

Substances:

Year:  1983        PMID: 6861786     DOI: 10.1007/bf00252888

Source DB:  PubMed          Journal:  Eur J Nucl Med        ISSN: 0340-6997


  8 in total

1.  A focusing collimator for research in scanning.

Authors:  J E FRANCIS; C C HARRIS; P R BELL
Journal:  J Nucl Med       Date:  1962-01       Impact factor: 10.057

2.  The significance of serum cholesterol in thyroid disease.

Authors:  J P PETERS; E B MAN
Journal:  J Clin Invest       Date:  1950-01       Impact factor: 14.808

3.  Comparative study of 111In and 59Fe bone marrow scanning.

Authors:  C Parmentier; F Therain; T P Charbord; B Aubert; N Morardet
Journal:  Eur J Nucl Med       Date:  1977-06-30

4.  59Fe whole-body scanning.

Authors:  T K Chaudhuri; J C Ehrhardt; R L DeGowin; J H Christie
Journal:  J Nucl Med       Date:  1974-08       Impact factor: 10.057

5.  Whole-body scanning of 59Fe for evaluating body distribution of erythropoietic marrow, splenic sequestration of red cells and hepatic deposition of iron.

Authors:  P Ronai; H S Winchell; H O Anger; J H Lawrence
Journal:  J Nucl Med       Date:  1969-07       Impact factor: 10.057

6.  Bone marrow imaging with 59Fe.

Authors:  W H van Zyl; M G Lötter; J C Kok; G J Maree; P C Minnaar; A van Aswegen; A Du P Heyns; M Iturralde; F P Retief
Journal:  S Afr Med J       Date:  1977-01-01

7.  Focusing collimators for use with the hard gamma emitters rubidium-86 and potassium-42.

Authors:  W D Love; R O Smith
Journal:  J Nucl Med       Date:  1966-10       Impact factor: 10.057

8.  A new stannous agent kit for labelling red blood cells with 99TCM and its clinical application.

Authors:  D Ducassou; D Arnaud; A Bardy; J Beydon; C Baquey
Journal:  Br J Radiol       Date:  1976-04       Impact factor: 3.039

  8 in total
  1 in total

1.  Feasibility of a 59Fe ferrokinetic study based on bone-marrow scans.

Authors:  E Kahn; B Aubert; C Parmentier; R Di Paola
Journal:  Eur J Nucl Med       Date:  1983
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.