Literature DB >> 685672

Fixation of pelvic fractures and dislocations. An experimental study on the loading of pelvic fractures and sacro-iliac dislocations after external compression fixation.

B Gunterberg, I Goldie, P Slätis.   

Abstract

A trapezoid external compression fixation frame, assembled with the Hoffman instruments, was used for stabilizing experimental injuries to the pelvic skeleton of ten cadaver specimens. The resistance to loading in a position corresponding to upright standing was tested in 17 experiments and related to the calculated load in vivo. The results indicated that ipsilateral injuries, either presenting as dislocations of the sacro-iliac joint and symphysis or as unilateral fractures of the sacrum or ilium in combination with fractures of the pubic rami could be stabilized by the external compression frame well enough to permit weight-bearing in the upright standing position. Bilateral injuries to the pelvic skeleton, vertical or oblique, could not, however, be stabilized enough to resist more than a fraction of the normal load in the upright standing position.

Entities:  

Mesh:

Year:  1978        PMID: 685672     DOI: 10.3109/17453677809005765

Source DB:  PubMed          Journal:  Acta Orthop Scand        ISSN: 0001-6470


  7 in total

1.  Orthopedics-epitomes of progress: external fixation.

Authors:  S H Anzel
Journal:  West J Med       Date:  1980-11

2.  13-Year experience in external fixation of the pelvis: complications, reduction and removal.

Authors:  P M Mitchell; C M Corrigan; N A Patel; A J Silverberg; S E Greenberg; R V Thakore; W T Obremskey; J M Ehrenfeld; J M Evans; M K Sethi
Journal:  Eur J Trauma Emerg Surg       Date:  2015-02-24       Impact factor: 3.693

3.  Comparative mechanical performances of some new devices for fixation of unstable pelvic ring fractures.

Authors:  H E Rubash; T D Brown; D D Nelson; D C Mears
Journal:  Med Biol Eng Comput       Date:  1983-11       Impact factor: 2.602

4.  External fixation of unstable pelvic ring fractures: comparative rigidity of some current frame configurations.

Authors:  T D Brown; J P Stone; J H Schuster; D C Mears
Journal:  Med Biol Eng Comput       Date:  1982-11       Impact factor: 2.602

5.  Modified triangular posterior osteosynthesis of unstable sacrum fracture.

Authors:  E Mouhsine; M Wettstein; C Schizas; O Borens; C-H Blanc; P-F Leyvraz; N Theumann; R Garofalo
Journal:  Eur Spine J       Date:  2005-04-21       Impact factor: 3.134

6.  Can a modified anterior external fixator provide posterior compression of AP compression type III pelvic injuries?

Authors:  Richard Martin Sellei; Peter Schandelmaier; Philipp Kobbe; Matthias Knobe; Hans-Christoph Pape
Journal:  Clin Orthop Relat Res       Date:  2013-09       Impact factor: 4.176

7.  The value of computerized tomography in fractures of the pelvic ring.

Authors:  P Hoffmeyer; J M Seigne; J Garcia; H Vasey
Journal:  Int Orthop       Date:  1984       Impact factor: 3.075

  7 in total