Literature DB >> 6853565

Quantitative gait analysis after total knee arthroplasty for monarticular degenerative arthritis.

S R Simon, H W Trieshmann, R G Burdett, F C Ewald, C B Sledge.   

Abstract

By quantitative gait analysis, we characterized the functional results of total knee arthroplasty in a group of twelve elderly patients with isolated degenerative arthritis of one knee. All patients had had a standard replacement arthroplasty performed at least two years before the study. In the gait analysis we used high-speed movie cameras synchronized with force platforms and electromyograms to provide kinetic and kinematic data. The data were compared with those obtained from an age-matched control group. In the patients most of the measurements of gait had been restored to normal levels. These measurements included: velocity; stride length; arcs of motion of the hip, knee, and ankle bilaterally; phasic muscle activity; and the amount of mechanical work performed. There were three patterns of external torque across the implants and in the control knee which were comparable in magnitude but varied in relative frequency between the two groups. As compared with the controls, the patients spent approximately 30 per cent more time in double-limb stance and had prolonged cycle times. These findings may have been the result of muscle weakness, neural impairment, or habit, but the cause could not be determined by this study.

Entities:  

Mesh:

Year:  1983        PMID: 6853565

Source DB:  PubMed          Journal:  J Bone Joint Surg Am        ISSN: 0021-9355            Impact factor:   5.284


  5 in total

1.  [Muscle biomechanics in total ankle replacement].

Authors:  V Valderrabano; B Hintermann; V von Tscharner; B Göpfert; W Dick; B M Nigg
Journal:  Orthopade       Date:  2006-05       Impact factor: 1.087

2.  Total knee replacement influences both knee and hip joint kinematics during stair climbing.

Authors:  Tuuli Saari; Roy Tranberg; Roland Zügner; Johan Uvehammer; Johan Kärrholm
Journal:  Int Orthop       Date:  2004-04       Impact factor: 3.075

3.  Comparison of gait kinetics in total and unicondylar knee replacement surgery.

Authors:  S Miller; A Agarwal; W B Haddon; L Johnston; G Arnold; W Wang; R J Abboud
Journal:  Ann R Coll Surg Engl       Date:  2018-02-27       Impact factor: 1.891

4.  Drift removal for improving the accuracy of gait parameters using wearable sensor systems.

Authors:  Ryo Takeda; Giulia Lisco; Tadashi Fujisawa; Laura Gastaldi; Harukazu Tohyama; Shigeru Tadano
Journal:  Sensors (Basel)       Date:  2014-12-05       Impact factor: 3.576

5.  Gait Analysis in Patients with Wide Resection and Endoprosthesis Replacement Around the Knee.

Authors:  Vivek Ajit Singh; Chan Wei Heng; Nor Faissal Yasin
Journal:  Indian J Orthop       Date:  2018 Jan-Feb       Impact factor: 1.251

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.